For a detailed instruction how to set up your netFIELD Device IO-Link Wireless Bridge, please follow the chapter "Mounting and commissioning" in the User Manual. → …\Documentation\User_Manuals\... MountingMounting without clip- Plug it onto the IO-Link Device to be connected
- Establish a cable connection from the Wireless Bridge to the IO-Link device
Mounting with clip- The clip is an easy-to-use retaining bracket to mount the Wireless Bridge to flanges, machines, equipment, and other flat surfaces
- With M3 screws or cable ties it can easily be fixed
Step-by-step instructions for commissioning the bridgeTo commission an IO-Link Device in an IO-Link wireless radio network using the Wireless Bridge, perform the following steps: - Connect the A-coded M12 supply connector of the Wireless Bridge to the power supply using a suitable M12 cable (24 V SELV/PELV power supply required). Make sure that the cable cross-section of the M12 cable is sufficiently large
- The power LED of the Wireless Bridge emits a green light. If this is not the case, check the power supply
- As soon as the Wireless Bridge is connected to the power supply, a reset cycle occurs. This takes a few seconds. During this period, the status LED shows a signal sequence in red, green, and blue
- As soon as the reset cycle is completed, the status LED starts flashing alternately purple and yellow
- Connect the IO-Link Device (sensor/actuator)
The status LED is flashing alternately purple and green Now, you can set up and configure the wireless data transfer of the Wireless Bridge
DocumentationDocumentation for all hard- and software components included in this Product DVD is available on the path: …\Documentation\... The Documentation Library on the Hilscher Knowledgebase includes further documents: https://kb.hilscher.com/display/DL/Documentation+Library+Home SupportIn case of questions, please do not hesitate to get in touch with your local Hilscher Support. E-Mail: support@hilscher.com Phone: +49 6190 9907 99 |