Technical Data
Feature | Description |
---|---|
Maximum number of input data | default setting: 128 bytes, maximum 1020 bytes |
Maximum number of output data | default setting: 128 bytes, maximum 1020 bytes |
Maximum number of receive PDOs | Standard Mode 0 … 255 (netX 50/100/500)default setting: 16 configurable: 0..512, for mapping objects 2200 … 2203 Extended Mode*
|
Maximum number of transmit PDOs | Standard Mode 0 … 255 (netX 50/100/500)default setting: 16 configurable: 0..512, for mapping objects 2000 … 2003 Extended Mode*
|
Exchange of process data |
|
Acyclic communication |
|
Functions |
|
Baud rates |
|
Data transport layer | CAN Frames |
CAN Frame type |
|
...
Info |
---|
Note: The actual maximum number of IO Data and PDOs depends on the available amount of memory. |
Configuration
For configuration of standard mode with default settings:
- by SYCON.net configuration software (Download or exported configuration file named
Packet API based configuration by host application
Data base configuration (config.nxd)
created by
netX Configuration tool
For configuration of standard mode with default settings and configured settings and extended mode:
- by packet to transfer configuration parameters.
Diagnostic
...
configuration tool
Diagnostic
- Dual-port memory: Common diagnostic via dual port memory
- API: Packet API bases diagnostic
- LED: Diagnostic LED