Software

...


...

To access the file system of your netIC, the tool ComProX from 1997 is needed. (B0.9.1_svn1997)

...

View file
nameB0.9.1_svn1997.zip
height250

ComProX

Open Device

After opening the ComproX tool, please open the corresponding COM interface

Image Modified

Image Modified

Force Bootloader

Select "Connection -> Force Bootloader" and reset your Evaluation Board while the "Entering Bootstart" window is open.

Image Modified

Open File Explorer

Now the SYS-LED on your netIC should flashes alternately green and yellow, the device is now in bootloader mode.
Via "Connection -> File Explorer" you can now access the file system of the device.

Download and Upload

By selecting the folder and right-clicking on a file or the right pane, you can perform a download or upload.

Image Modified