    In standard mode, the following values and limitations apply:

    Technical Data for default Settings

    Features

    Parameter
    Default number of input data
    • 512 bytes (netX 50/100/500)
    • 64 bytes (netX 10)
    Default number of output data
    • 512 bytes (netX 50/100/500)
    • 64 bytes (netX 10)
    Default number of receive PDOs
    • 64 (netX 50/100/500)
    • 8 (netX 10)
    Default number of transmit PDOs
    • 64 (netX 50/100/500)
    • 8 (netX 10)
    Info

    Note: The EDS files for Hilscher standard products contain the functionality that matches the default settings. SYCON.net and the netX Configuration tool only configure the default settings.