Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents

Software

...


To access the file system of your netIC, the tool ComProX from 1997 is needed. (B0.9.1_svn1997)

...

View file
nameB0.9.1_svn1997.zip
height250

ComProX

Open Device

After opening the ComproX tool, please open the corresponding COM interface

Image Modified

Image Modified

Force Bootloader

Select "Connection -> Force Bootloader" and reset your Evaluation Board while the "Entering Bootstart" window is open.

Image Modified

Open File Explorer

Now the SYS-LED on your netIC should flashes alternately green and yellow, the device is now in bootloader mode.
Via "Connection -> File Explorer" you can now access the file system of the device.

Download and Upload

By selecting the folder and right-clicking on a file or the right pane, you can perform a download or upload.

Image Modified

Please make an upload of all files in every folder and pay attention not to mix up the same named INIBATCH.NXD, when downloading to another netIC and to safe them in the correct filesystem folder.