Multiexcerpt | ||
---|---|---|
| ||
The data below applies to CANopen Slave firmware and stack version 5.x.x.x The firmware/stack has been designed in order to meet the CiA Work Draft 301 V4.2.0 specification. |
...
Section | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Column | Key Features | width | ||||||||||||||||||||||||||
Column | ||||||||||||||||||||||||||||
Panel | title |
Table of Contents |
---|
Technical Data
Feature | Description |
---|---|
number of input data | standard mode default setting: 128 bytes, extended mode: maximum 1020 bytes |
number of output data | standard mode default setting: 128 bytes, extended mode: maximum 1020 bytes |
number of receive PDOs | standard mode default setting: 16 extended mode: 0..512, for mapping objects 2200 … 2203 |
number of transmit PDOs | standard mode default setting: 16 extended mode: 0..512, for mapping objects 2000 … 2003 |
Exchange of process data |
|
Acyclic communication |
|
Functions |
|
Baud rates |
|
Data transport layer | CAN Frames |
CAN Frame type |
|
*: In extended mode, the stack offers extended functionality. To use these functions requires an application program that configures and supports these functions, e.g. to create an own object dictionary. In extended mode, more input and output data can be used and transmit and receive PDOs can be used.
...
Note: The actual maximum number of IO Data and PDOs depends on the available amount of memory. Configuration
Diagnostic
|