1. SYCON.net

In SYCON.net are two PROFINET controller available.

...

CIFX RE/PNM V3 is for PROFINET IO Controller V3. This is the new PROFINET controller with PROFINET specification V2.3x and can run in RT or IRT mode.

Image Modified


2. V3 PROFINET Controller for IRT

For IRT the port-to-port connections must be configured. For this, SYCON.net creates two views:

  • Network View
  • Topology View:


Network View

Image Modified

Topology View:

Image Modified


3. Add netX90 device

Install the GSDML file from the extendedConfig example.

The extendedConfig example can be found in the Knowledge Base on the following website:

netX 90: https://kbhilscher.hilscheratlassian.comnet/wiki/display/NXLFWHST/netX+90+-+PROFINET+IO+Device+-+Examples


The GSDML file can be found in the netXStudio project in Project Explorer at:

...

Go to the device catalogue and add the netX90 device.

Image Modified


Switch to Topology View and connect Port 1 from PROFINET IO Controller with Port 1 from PROFINET IO Device.

Take care, that the ports of the hardware is really connected like configured.

Image Modified


4. Set IRT Mode in the controller and device

Choose the controller:

Image Modified


Choose the device:

Image Modified


5. Download this Configuration in the IO Controller

Image Modified


The IO Controller starts an IRT connection to the IO Device.

Note: Do not install a switch or other devices between IO Controller Port1 and IO Device Port1, only a netANALYZER or a special device like a TAP can be used to create a trace of this communication , because such device do not interrupt the IRT communication.

...