The data below applies to CANopen Slave firmware and stack version 3.5.x. The firmware/stack has been designed in order to meet the CiA Work Draft 301 V4.02 specification.
Key Features
- Node guarding / life guarding and heartbeat
- SYNC protocol
- Emergency messages
Supported Protocols
- CANopen
- CAN Layer 2 Messages through Packet Interface
Technical Data
Feature | Description |
---|---|
Maximum number of input data | 1020 bytes |
Maximum number of output data | 1020 bytes |
Maximum number of receive PDOs | Standard Mode
Extended Mode*
|
Maximum number of transmit PDOs | Standard Mode
Extended Mode*
|
Exchange of process data |
|
Acyclic communication |
|
Functions |
|
Baud rates |
|
Data transport layer | CAN Frames, can be accessed by programming the CAN DL layer |
CAN Frame type |
|
*: In extended mode, the stack offers extended functionality. To use these functions requires an application program that configures and supports these functions, e.g. to create an own object dictionary. In extended mode, more input and output data can be used and transmit and receive PDOs can be used.
Note: The actual maximum number of IO Data and PDOs depends on the available amount of memory.
Configuration
For configuration of standard mode with default settings:
- by SYCON.net configuration software (Download or exported configuration file named config.nxd)
- by netX Configuration tool
For configuration of standard mode with default settings and configured settings and extended mode:
- by packet to transfer configuration parameters.
Diagnostic
Firmware supports common and extended diagnostic in the dual-port-memory for loadable firmware