Reset netFIELD Evaluation Kit back to Factory Settings
Request for fitting image
To be able to reset the netFIELD Evaluation Board, please always contact the Hilscher support team first.
Since there is a specific MAC-Address on the FDL of the device, this could be overwritten if flashed by yourself.
Therefore the support team needs the specific Serialnumber of the netRAPID, which is part of the Device.
At best, please provide all available Barcodes on the netFIELD Evaluation board.
ā required
ā optional
Based on this information, it is possible to generate a suitable image, which can be flashed via JTAG with netX Studio.
Flashing an Image
The Flasher is integrated into netX Studio and can be found in the section "Tools ā Flasher".
Please select the interface, with which the netFIELD Device can be accessed.
Therefore a JTAG Adapter is needed. Please follow this link, to find a list of supported adapters: JTAG Debug Probes for netX 90
the File "eflash.bin", needs to be flashed into the external flash of the device.
Therefore select Flash Type "Serial Flash (SQI)"
The File "iflash01_offset_0x3000.bin" needs to be flashed to the internal Flash in Area 0 and 1.
The file "iflash2.bin" needs to be flashed to the internal Flash in Area 2 (APP).
The device is now set back to factory condition.