Reset netFIELD Evaluation Kit back to Factory Settings

Request for fitting image

To be able to reset the netFIELD Evaluation Board, please always contact the Hilscher support team first.

Since there is a specific MAC-Address on the FDL of the device, this could be overwritten if flashed by yourself.


Therefore the support team needs the specific Serialnumber of the netRAPID, which is part of the Device.

At best, please provide all available Barcodes on the netFIELD Evaluation board.

ā†’ required

ā†’ optional


Based on this information, it is possible to generate a suitable image, which can be flashed via JTAG with netX Studio.


Flashing an Image

The Flasher is integrated into netX Studio and can be found in the section "Tools ā†’ Flasher".


Please select the interface, with which the netFIELD Device can be accessed.

Therefore a JTAG Adapter is needed. Please follow this link, to find a list of supported adapters: JTAG Debug Probes for netX 90


the File "eflash.bin", needs to be flashed into the external flash of the device.

Therefore select Flash Type "Serial Flash (SQI)"


The File "iflash01_offset_0x3000.bin" needs to be flashed to the internal Flash in Area 0 and 1.

Please note that the offset is set to address 0x3000, otherwise the FDL could be overwritten.


The file "iflash2.bin" needs to be flashed to the internal Flash in Area 2 (APP).

Please do not forget to set back the offset to address 0x00.

The device is now set back to factory condition.