Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleRelease Notes
Page Properties
Status

Status
colourYellow
titleBETA
      

Release Date

 

Version1.0.0.0
Summary
  • First Release with support of PROFINET IO Device, EtherNet/IP Adapter including OPC-UA Server and MQTT Client

Note: We reserve the right to make technical changes without prior notice.


Direct Selling - Preloaded communication module

The Device is sold as a product directly by Hilscher Gesellschaft für Systemautomation mbH.

1912.102

Device Branding - for machine and plant construction customer sold by Hilscher HQ

  • Ready-to-use IP67 module
  • Branded and preloaded software
  • Precertified firmware and hardware
  • Production at Hilscher HQ
  • Business requirement is quantity > 1000 pieces

Basic paket

netFIELD IO-Link Wireless Master - Device Branding
  • NFD-IOLM\W-Device_Branding

Extension Pakets

netFIELD IO-Link Wireless Master - Product Item

  • NFD-IOLM\W-Device_Branding_EXT

netFIELD IO-Link Wireless Master - Color Scheme

  • NFD-IOLM\W-Device_Branding_Col

netFIELD IO-Link Wireless Master - Documentation

  • NFD-IOLM\W-Device_Branding_Doc

PCB Branding - for machine and plant construction customer sold by Hilscher HQ

  • Branded and preloaded software
  • Precertificied firmware
  • Production at Hilscher HQ
  • Plastic housing is not desired
    *) Housing is defined and served by manufacturer
  • PCB modification according the Declaration of Conformity
  • Business requirement is quantity > 1000 pieces

Basis Pakets

NFD-IOLM\W-PCB_Branding - (netFIELD IO-Link Wireless Master - PCB Branding Basis Paket)

  • Read the mounting instructions and the safety instructions on connecting and commissioning the device.
  • Disconnect the system to which the device will be mounted from the power supply.
    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titlenetFIELD Device IO-Link Wireless Master - Business Model
    Section
    Column
    width50%
    Part numberProduct NameScope of Delivery
    netFIELD IO-Link Wireless Master - Direct Selling
    • NFD-3090-PNS-IOLM\W
    • Antennas
    • Product DVD
    • Access to KB Product Area
    • Firmware Update
    1912.122netFIELD IO-Link Wireless Master - Direct Selling
    • NFD-3090-EIS-IOLM\W
    Column
    width50%
    Part numberScope of Delivery
    0330.000First communication protocol / incl. tests
    • Available protocols
      • PROFINET IO Device
      • EtherCAT Slave
      • EtherNet/IP Adapter
    • Modification firmware
      • Web-page design
      • Logo
      • MAC adress range
      • Certification network protocol (PI, ETG, ODVA)

        • Vendor ID´s
        • Manufacturer ID´s
    • User-Manual - raw formated word document
    • Project management
    Modification housing
    • Housing
      • Plastic
      • Color light grey (RAL 7035)
    • Laser printing
      • laser programming for first product item
    • Cast resin filling
      • Solvent-free electrical casting resin system based on 2-component polyurethane
      • Colors are availabel in natrual or black
    IO-Link Configuration Tool / Technology
    • Branding
    • Logo

    IO-Link Wireless Technology

    Conformance testing (certification)

    • PROFINET Device Class C PI certification tests
    • EtherCAT Slave ETG

      • Single Device - First Time Testing
    • EtherNet/IP Adapter - ODVA Conformance Test
      • Single Product Test

    Radio approval testing (certifcation)

    • RED - Richtlinie 2014/53/EU

    • FCC - Federal Communications Commission
    • ISED - Innovation, Science and Economic Development Canada
    Part numberScope of Delivery
    0330.001

    Product Item - each further communication protocol / incl. tests

    • Available protocols
      • PROFINET IO Device
      • EtherCAT Slave
      • EtherNet/IP Adapter
    • Contains modification subjects of pos.10
    • User Manual - raw formated word document
    • Project managment
    Part numberScope of Delivery
    0330.002

    Color Scheme - Basic costs for setup and project

    • Housing material plastic
    • RAL color must be sent with the order
    • For each housing with individual color scheme
    • Project -management

    Laser printing

    • Laser programming for each product item
    • Project -management

    Function samples

    • netFIELD Wireless Master branded
    • housing with individual color scheme
    • laser print with individual signs and color scheme
    Part numberScope of Delivery
    0330.200

    Extension Documentation

    • User Manual Branding
    • Logo
    • Model name
    • Company related parameters
    Column
    width50%
    Part numberScope of Delivery
    0330.100

    First communication protocol / incl. tests

    • Available protocols
      • PROFINET IO Device
      • EtherCAT Slave
      • EtherNet/IP Adapter
    • Modification firmware
      • Web-page design
      • Logo
      • MAC adress range
      • Certification network protocol (PI, ETG, ODVA)

        • Vendor ID´s
        • Manufacturer ID´s
    • User-Manual - raw formated word document
    • Project management

    IO-Link Configuration Tool / Technology

    • Branding
    • Logo

    IO-Link Wireless Technology

    PCB modification

    • PCB modification are limited to the size, in the magnification of the printed circuit board without changes of the copper layer

    • PCB branding within the the framework the passed conformity of the EMV tests, Radio approval tests and protocol conformance tests

    Hardware test adapter modification

    • according to the PCB modification
    • End-Of Line Test rework

    Conformance testing (certification)

    • PROFINET Device Class C PI certification tests
    • EtherCAT Slave ETG
      • Single Device - First Time Testing
    • EtherNet/IP Adapter - ODVA Conformance Test
      • Single Product Test

    Radio approval testing (certifcation)

    • RED - Richtlinie 2014/53/EU

    • FCC - Federal Communications Commission
    • ISED - Innovation, Science and Economic Development Canada
    Panel
    bgColor#FFFFFF
    titleBGColorlightgrey
    titleGetting Started
    StepDescrition

    Requirements and preparation

    • Prepare the device installation and commissioning according to the requirements descriptions on hardware, system and software.
    • Prepare the required mounting tools.

    Safety

    Mounting

    • Mark the positions to fasten the device with screws and cut the M4 holes.
    • Fasten the device with the screws.
    • Ground the device.
    • Mount all three SMA antennas.

    Connecting and booting

    • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
    • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
    • Connect the +24 V DC SELV or PELV power supply to the sensor/actuator.
    • Switch on the power supply units of the device and of the sensors/actuators.

    Commissioning PROFINET IO Device

    • Configure the PROFINET IO-Controller: Import the GSDML file:
      GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-20200624.xml
      This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
      GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-NOCONFIG-20200624.xml
      This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
    • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
    • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
    • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
    • Configure the IO-Link sensors/actuators.

    Commissioning EtherNet/IP Adapter

    • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
    • Configure the EtherNet/IP Scanner: Import the EDS file:
      HILSCHER_NETFIELD_V1.1_IOL_W.EDS
    • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
    • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
    • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
    • Configure the IO-Link sensors/actuators.

    Documentation

    Documentation for all hard- and software components included in this Product DVD is available on the path: …\Documentation\...

    The Documentation Library on the Hilscher Knowledgebase includes further documents: https://kb.hilscher.com/display/DL/Documentation+Library+Home

    Support

    In case of questions, please do not hesitate to get in touch with your local Hilscher Support.       

    E-Mail: support@hilscher.com

    Phone: +49 6190 9907 99


    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleDownload

    Firmware: netFIELD Firmware 2021-08-1 - BETA.zip

    Device Description: DeviceDescription.zip


    Excerpt
    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleSupported Protocols

    CC-Link IE Field Basic

    Slave

    EtherCAT

    Slave

    EtherNet/IP

    Adapter

    Modbus/TCP

    Client/Server

    POWERLINK

    Controlled Node

    PROFINET IO

    Device

    Sercos

    Slave

    VARAN

    Client

    netFIELD IO-Link Wireless Master

    (error)(error)(Haken)(error)(error)(Haken)(error)(error)
    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleProduct Features
    netFIELD IO-Link Wireless types

    Protocol support

    (for more details, please see the Technology section)

    IO-Link Wireless support


    Real-Time Ethernet Slave

    OPC UA Server
    & MQTT Client
    Raw Ethernet (NDIS)TCP socket interfaceIntegrated WebServer

    Pairing-Service

    Scan-Service

    Controlled roaming

    Frequency-Hopping Blacklisting mechanism
    NFD-3090-PNS-IOLM\W

    (tick)

    PROFINET IO

    (tick)(minus)(tick)(tick)(tick)(tick)(minus)(tick)(tick)
    NFD-3090-EIS-IOLM\W

    (tick)

    EtherNet/IP

    (tick)(minus)(tick)(tick)(tick)(tick)(minus)(tick)(tick)


    Note:

    IO-Link Wireless Feature Description

    • Pairing-Service: Pair devices with the appropriate master
    • Scan-Service: Add “un-paired” devices to the system
    • Controlled roaming of devices between diff erent masters
    • Frequency-Hopping to switch to free, unused frequency bands
    • Blacklisting mechanism to ensure the co-existence with other wireless systems
    Panel
    bgColor#FFFFFF
    titleBGColorlightgrey
    titleChanges in this version
    Section
    Column
    width50%

    General

    • First Release Version
    Column
    width50%

    Specific functionality

    • Industrial Ethernet
      • PROFINET IO Device
      • EtherNet/IP Adapter
    • Diagnosis infaces
      • OPC-UA Server
      • MQTT Client
    • IO-Link Wireless Master
      • Supports up to 16 Wireless IO-Link Device simultaneously via two parallel transmission tracks
      • Scan mode, simple pairing of discoverable IO-Link devices
      • Wireless range of point-to-point communication up to 10 meter
    • Robust IP67 design
    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleDocumentation
    Section
    Column
    width50%

    User manual netFIELD IO-Link Wireless Master PROFINET IO-Device

    View file
    namenetFIELD IO-Link Wireless NFD-3090-PNS-IOLM_W UM 02 EN.pdf
    height250

    Column
    width50%

    User manual netFIELD IO-Link Wireless Master EtherNet/IP Adapter

    View file
    namenetFIELD IO-Link Wireless NFD-3090-EIS-IOLM_W UM 02 EN.pdf
    height250

     Return to overview page...