Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleRelease Notes
Page Properties
Status

Status
colourGreen
titleRELEASE

Release Date

 

Version1.2.0.0

Summary

Release with support of PROFINET IO Device, EtherCAT Slave and EtherNet/IP Adapter including OPC-UA Server and MQTT Client.

Contains IO-Link ET application for configuration of the IO-Link Wireless Masters from Hilscher and connected IO-Link devices.

Note: We reserve the right to make technical changes without prior notice.

Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleTable of contents
  1. Getting started
  2. Documentation
  3. Firmware Version
  4. Configuration Tool
  5. Hardware and Protocols
  6. Radio Approvals
  7. Product Download Package


Anchor
start
start

Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleGetting Started

Software Installation

Expand
titleSoftware Installation - IO-Link

Configuration Tool IO-Link ET

Install IO-Link ET on your computer to configure IO-Link Masters NFD-6090-xxx-IOLMA\M12 and NFD-3090-xxx-IOLM\W and connected IO-Link Devices.

(xxx means PNS for PROFINET IO, EIS for EtherNet/IP and ECS for EtherCAT)

→ …\Software_&_Tools\IO-Link_ET\...

First Steps

Expand

For a detailed instruction how to set up your netFIELD Device IO-Link Wireless Master, please follow the chapter "Getting Started" in the User Manual.

→ …\Documentation\User_Manuals\...

Mounting

  • Mark the positions to fasten the device with screws and cut the M4 holes.
  • Fasten the device with the screws.
  • Ground the device.
  • Mount all three SMA antennas.

Connecting and booting

  • Connect the Ethernet M12 cable to the NFD-3090-PNS-IOLM\W device and to the PLC (PROFINET IO-Controller).
  • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-PNS-IOLM\W device
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
  • Connect the +24 V DC SELV or PELV power supply to the IO-Link Device.
  • Switch on the power supply units of the device and of the IO-Link Device.

Commissioning PROFINET IO Device

  • Configure the PROFINET IO-Controller: Import the GSDML file:
    ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-EXPERT-20210707.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
     ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-PDCT-20210623.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
  • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
  • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
  • Configure the IO-Link Device.

Commissioning EtherCAT Slave

  • For the first commissioning, the NFD-3090-ECS-IOLM\W device requires a DHCP server.
  • In the configuration software of the EtherCAT Master:
    • Configure the EtherCAT Master: Import the EDS file:
      ...\Firmware_&_EDS\DeviceDescription\EtherCAT\... Hilscher_netFIELD_Wireless.xml.
    • Create the configuration project with EtherCAT Master and EtherCAT Slave, select the modules and submodules and set the parameters.
  • For the subsequent steps the following configuration tools can be used:
    • Configure the IO-Link Wireless Master NFD-3090-ECS-IOLM\W using the netFIELD Wireless Web Server.
    • Configure the wireless IO-Link port parameters via the configuration software of the EtherCAT Master or using the netFIELD Wireless Web Server.
    • Configure the IO-Link Device.

Commissioning EtherNet/IP Adapter

  • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
  • Configure the EtherNet/IP Scanner: Import the EDS file:
    ...\Firmware_&_EDS\DeviceDescription\EtherNetIP\... HILSCHER-NETFIELD-WIRELESS-V2.1.EDS
  • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
  • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
  • Configure the IO-Link Device.

Documentation

Documentation for all hard- and software components included in this Download Package is available on the path: …\Documentation\...

The Documentation Library on the Hilscher Knowledgebase includes further documents: https://kb.hilscher.com/display/DL/Documentation+Library+Home

Support

In case of questions, please do not hesitate to get in touch with your local Hilscher Support.       

E-Mail: support@hilscher.com

Phone: +49 6190 9907 99


Anchor
doc
doc

Panel
bgColor#ffffff
titleBGColorlightgrey
titleDocumentation

Page Properties Report
firstcolumnPage
spacesDL
headingsDocument type, Document title, Content, Date, Language, File type
labelnetx51_documentation_current_release
reverseSorttrue
cqllabel in ("doc201101um02en","doc200701um02en","doc210501um01en") and space = "DL"

The documentation can be downloaded at:


Anchor
fwver
fwver

Panel
bgColor#ffffff
titleBGColorlightgrey
titleFirmware, EDS, Examples

Product Update Firmware

Version

Description

netFIELD Device IO-Link Wireless Master 

  • PROFINET IO Device
  • EtherCAT Slave
  • EtherNet/IP Adapter
V2.2.0.5

Product Update Integration Firmware:

  • netFIELD Device Application layer firmware
  • netFIELD Device Communication protocol incl. IO-Link Wireless Master firmware
  • netX 90 Maintenance firmware - standalone firmware for system recovering and download functions


Anchor
conftool
conftool

Panel
bgColor#ffffff
titleBGColorlightgrey
titleConfiguration Tool

IO-Link ET

Operating System Windows 10macOS 10.11Linux
Status(tick)(tick)(tick)
System requirements
  • 32 bit
  • 64 bit
  • Apple M1
  • Intel chips
  • 64bit only
  • Ubuntu 18.04 and newer
  • Fedora 24 and newer
  • Debian 8 and newer

Anchor
hw_fw
hw_fw

Panel
bgColor#ffffff
titleBGColorlightgrey
titleHardware and Protocols
Industrial network
CC-Link IE Field Basic Slave(minus)
EtherCAT Slave(tick)
EtherNet/IP Adapter(tick)
Modbus/TCP Client/Server(minus)
POWERLINK Controlled Node(minus)
PROFINET IO Device(tick)
Sercos Slave(minus)
VARAN Client(minus)


Anchor
radio
radio

Panel
bgColor#ffffff
titleBGColorlightgrey
titleRadio Approvals

RED - Richtlinie 2014/53/EU

Radio equpiment directive

Area: Europe incl. EFTA states

(tick)

FCC Identification number

Federal Communications Commission

Area: United States of America

ID: 2ANEG-0002

(tick)

ISED certification label

Innovation, Science and Economic Development Canada

Area: Canada

ID:24152-0002

(tick)


Anchor
download
download

Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleProduct Download Package

Attachments
previewfalse
uploadfalse
oldfalse
patterns*.zip
sortOrderdescending
sortBysize