As an example the Allen Bradley Point I/O Module Adapter "1734 AENT" is used, together with the fitting Point I/O Modules "1734 IB8" and "1734 OB8E".
Configuration Example
Hardware configuration
Slot | Module Name | EDS File |
---|---|---|
0 | 1734-AENT | 0001000C006C0300.eds |
1 | 1734-IB8 | 0001000700D80300.eds |
2 | 1734-OB8E | 0001000700DA0300.eds |
The EDS File of each module is needed for further configuration of the Generic Modular Adapter.
These can be found on the Rockwell Automation Page:
Software Configuration
Add Modules
In SYCON.net, add an EtherNet/IP Scanner (e.g. CIFX RE/EIM) and then add an ENIP Modular Generic Adapter to the network.
Open the Configuration Window of the Modular Generic Adapter an choose "Modules" in the Navigation Area.
Change “Slots in Rack” to 3 and add the modules: