The basic circuit (source: technical data reference guide) is shown below.
with With the following values: Symbol | Min | Typ | Max | Unit | BOD | 0 |
| 3.6 | V | BOD_T | 1.11 | 1.14 | 1.17 | V | BOD_H | 47 | 60 | 73 | mV | BOD_P | 5 |
| 20 | μs | The 24V is splitt split up by the resistors R1 and R2. If it will drop drops below 1.14V with an hystresis of 60mV for more than 5μs to 20μs with a hysteresis of 60mV, an internal signal is generated. The usage of this signal will depend on the kind of power supply that was monitored and how it is available inside the system. In the netX90 the internal signal is bound to a bit of a register in the asic_ctrl and as an interrupt input of the nested vector interrupt controller (NVIC). The generated interupt interrupt might be used in case that the supervised voltage was the main power supply to finish critical tasks and close non-reentrant contexts. |