Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section
Column
width35%

Key Features

Excerpt
  • Feature 1
  • Feature 2Isochronous produce and consume of cyclic data (SCP_Sync)
  • UC channel for transmission and reception of non-SIII-Ethernet-frames (SCP_NRT)
Column
width35%

Supported Protocols

  • Protocol 1
  • Protocol 2
Column
width30%
Panel
titleOn this page

Table of Contents

 

Technical Data

...

FeatureDescription
  
  

Configuration

Configuration by ...

Diagnostic

Firmware/stack available for netX

netX50, netX100, netX500

Maximum number of cyclic input data (Tx) of all slaves

200 bytes (including Connection Control)

Maximum number of cyclic output data (Rx) of all slaves

200 bytes (including Connection Control)

Maximum number of slave devices (netX 50)

8

Maximum number of slave devices (netX100, netX500)

5

Maximum number of applicable SERCOS addresses

512 (1 … 511)

Minimum cycle time

250 µs

Topology

Line and ring

Communication phases

NRT, CP0, CP1, CP2, CP3, CP4

Acyclic Communication (Service Channel)

Read/Write/Standard Commands

Baud rate

100 MBit/s

Data transport layer

Ethernet II, IEEE 802.3

Supported SERCOS III version

Communication Specification Version 1.1.2

Supported SERCOS Communication Profiles

SCP_FixCFG Version 1.1.1

SCP_VarCFG Version 1.1.1

SCP_VarCFG Version 1.1.3

Supported User SCP Profiles

SCP_WD Version 1.1.1

SCP_Diag Version 1.1.1

SCP_RTB Version 1.1.1

SCP_Mux Version 1.1.1

SCP_Sig 1.1.1

Supported FSP profiles

FSP_IO

FSP_Drive

SCP Sync support

yes

SCP_NRT support

yes

Identification LED feature supported

yes

Storage location of object dictionary

mixed mode

Configuration

Configuration is done by sending packets to the stack or by using SYCON.net configuration database.

Diagnostic

The Firmware supports diagnosis through the "Diagnostic Number" (S-0-0390).