Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

FeatureDescription

Firmware/stack available for netX

netX 50, netX 51, netX 52, netX 100, netX 500

netX 50, netX 51, netX 52:

Max. number of cyclic input data (Tx) of all slaves

254 bytes (including Connection Control and IO Status)

netX 50, netX 51, netX 52:

Max. number of cyclic output data (Rx) of all slaves

254 bytes (including Connection Control and IO Control)

 

netX 100, netX 500: Maximum number of cyclic input data

(Tx) of all slaves

 128 bytes (including Connection Control and IO Status)
 

netX 100, netX 500: Maximum number of cyclic output

data (Rx) of all slaves

 128 bytes (including Connection Control and IO Control)

Maximum number of slave devices

netX 52: 1

All others: 8

Maximum number of applicable SERCOS addresses

1 … 511

Minimum cycle time

250 µs

Topology

Line and ring

Communication phases

NRT, CP0, CP1, CP2, CP3, CP4

Acyclic Communication (Service Channel)

Read/Write/Standard Commands

Baud rate

100 MBit/s

Data transport layer

Ethernet II, IEEE 802.3

Supported SERCOS III version

Communication Specification Version 1.1.2

Supported SERCOS Communication Profiles

SCP_FixCFG Version 1.1.1

SCP_VarCFG Version 1.1.1

SCP_VarCFG Version 1.1.3

Supported User SCP Profiles

SCP_WD Version 1.1.1

SCP_Diag Version 1.1.1

SCP_RTB Version 1.1.1

SCP_Mux Version 1.1.1

SCP_Sig 1.1.1

Supported FSP profiles

FSP_IO

FSP_Drive

SCP Sync support

yes

SCP_NRT NRTPC support

yes

S/IP supportyes

Identification LED feature supported

yes

Storage location of object dictionary

mixed mode

...