Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section
Column
width35%

Key Features

Excerpt
  • Feature 1
  • Feature 2PROFIBUS DP-V0
  • PROFIBUS DP-V1 class 1 and 2
  • Automatic baud rate detection
Column
width35%

Supported

Protocols
  • Protocol 1
  • Protocol 2

    State Machines

    • FSPMS (Fieldbus Service Protocol Slave state machine)
    • MSCY1S (Master to Slave cyclic state machine)
    • DMPMS (Data Link Mapping Protocol Slave state machine)
    • MSAC1S (Data Link Mapping Protocol Slave state machine)
    • MSAC2S (Master Class2 to Slave acyclic state machine)
    • MSRM2S (Master Class2 to Slave resource Manager state machine)
    Column
    width30%
    Panel
    titleOn this page

    Table of Contents

     

     

     

    Technical Data

     
    FeatureDescription
    Maximum number of total cyclic input data 244 bytes
    Maximum number of total cyclic output data  244 bytes
    Maximum number of acyclic read/write240 bytes
    Configuration dataMax. 244 bytes
    Parameter data237 bytes application specific parameters
    Acyclic communication

    DP V1 Class 1 Read/Write

    DP V1 Class 1 Alarm

    DP V1 Class 2 Read/Write/Data Transport

    Baud rate

    Fixed values ranging from 9,6 kBits/s to 12 MBit/s

    Auto-detection mode is supported
    Data transport layerPROFIBUS FDL

    Configuration

    Configuration is done by sending packets to the stack transfer warm start parameters or by using SYCON.net configuration database.

    Diagnostic

    ...

    ...

    Firmware supports common and extended diagnostic in the dual-port-memory for loadable firmware.