Request for fitting image

To be able to reset the netFIELD Evaluation Board, please always contact the Hilscher support team first.

Since there is a specific MAC-Address on the FDL of the device, this could be overwritten if flashed by yourself.


Therefore the support team needs the specific Serialnumber of the netRAPID, which is part of the Device.

At best, please provide all available Barcodes on the netFIELD Evaluation board.

Image Added

Image Added→ required

Image Added→ optional


Based on this information, it is possible to generate a suitable image, which can be flashed via JTAG with netX Studio.


Flashing an Image

The Flasher is integrated into netX Studio and can be found in the section "Tools → Flasher".

Image Added


Please select the interface, with which the netFIELD Device can be accessed.

Therefore a JTAG Adapter is needed. Please follow this link, to find a list of supported adapters: JTAG Debug Probes for netX 90

Image Added


the File "eflash.bin", needs to be flashed into the external flash of the device.

Therefore select Flash Type "Serial Flash (SQI)"

Image Added


The File "iflash01_offset_0x3000.bin" needs to be flashed to the internal Flash in Area 0 and 1.

Note
Please note that the offset is set to address 0x3000, otherwise the FDL could be overwritten.

Image Added


The file "iflash2.bin" needs to be flashed to the internal Flash in Area 2 (APP).

Note
Please do not forget to set back the offset to address 0x00.

Image Added

The device is now set back to factory condition.