Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Import Macro Repair
Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleRelease Notes
Page Properties
Status

Status
colourYellowGreen
titleBETARELEASED
      

Release Date

31 Aug  

Version1.0.0.0
Summary

First Release with support of PROFINET IO Device, EtherNet/IP Adapter including OPC-UA Server and MQTT Client

Note: We reserve the right to make technical changes without prior notice.


Panel
bgColor#FFFFFF
titleBGColorlightgrey
titleGetting Started

First Steps

For a detailed instruction how to set up your netFIELD Device IO-Link Wireless Master, please follow the chapter "Getting Started" in the User Manual.

→ …\Documentation\User_Manuals\...

Mounting

  • Mark the positions to fasten the device with screws and cut the M4 holes.
  • Fasten the device with the screws.
  • Ground the device.
  • Mount all three SMA antennas.

Connecting and booting

  • Connect the Ethernet M12 cable to the NFD-3090-PNS-IOLM\W device and to the PLC (PROFINET IO-Controller).
  • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-PNS-IOLM\W device
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
  • Connect the +24 V DC SELV or PELV power supply to the sensor/actuator.
  • Switch on the power supply units of the device and of the sensors/actuators.

Commissioning PROFINET IO Device

  • Configure the PROFINET IO-Controller: Import the GSDML file:
    ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-20200624EXPERT-20210707.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
     ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-NOCONFIGPDCT-2020062420210623.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
  • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
  • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
  • Configure the IO-Link sensors/actuators.

Commissioning EtherNet/IP Adapter

  • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
  • Configure the EtherNet/IP Scanner: Import the EDS file:
    HILSCHER_NETFIELD_V1.1_IOL_W...\Firmware_&_EDS\DeviceDescription\EtherNetIP\... HILSCHER-NETFIELD-WIRELESS-V2.1.EDS
  • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
  • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
  • Configure the IO-Link sensors/actuators.

Documentation

Documentation for all hard- and software components included in this Product DVD is available on the path: …\Documentation\...

The Documentation Library on the Hilscher Knowledgebase includes further documents: https://kbhilscher.hilscheratlassian.comnet/wiki/display/DL/Documentation+Library+Home

Support

In case of questions, please do not hesitate to get in touch with your local Hilscher Support.       

E-Mail: support@hilscher.com

Phone: +49 6190 9907 99


Excerpt
Panel
bgColor#ffffff
titleBGColorlightgrey
title
Download
excerpt
Firmware & EDS

Firmware: netFIELD Firmware 2021-08-1 - BETA.zip

Device Description: DeviceDescription.zip

#FFFFFF

Specific functionality

  • Industrial Ethernet
    • PROFINET IO Device
    • EtherNet/IP Adapter
  • Diagnosis infaces
    • OPC-UA Server
    • MQTT Client
  • IO-Link Wireless Master
    • Supports up to 16 Wireless IO-Link Device simultaneously via two parallel transmission tracks
    • Scan mode, simple pairing of discoverable IO-Link devices
    • Wireless range of point-to-point communication up to 10 meter
  • Robust IP67 design

    Product Update Firmware

    Version

    Description

    netFIELD Device IO-Link Wireless Master 

    • PROFINET IO Device
    • EtherNet/IP Adapter
    V2.1.1.3

    Product Update Integration Firmware:

    • netFIELD Device Application layer firmware
    • netFIELD Device Communication protocol incl. IO-Link Wireless Master firmware
    • netX 90 Maintenance firmware - standalone firmware for system recovering and download functions

    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleSupported Protocols

    CC-Link IE Field Basic

    Slave

    EtherCAT

    Slave

    EtherNet/IP

    Adapter

    Modbus/TCP

    Client/Server

    POWERLINK

    Controlled Node

    PROFINET IO

    Device

    Sercos

    Slave

    VARAN

    Client

    netFIELD IO-Link Wireless Master

    (minus)(error)(error)(Haken)(error)(error)(Haken)(error)(error)

    (minus)

    (in preparation)

    (tick)(minus)(minus)(tick)(minus)(minus)
    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleProduct Features

    (for more details, please see the Technology section)

    netFIELD IO-Link Wireless types

    Protocol support

    IO-Link Wireless support


    Real-Time Ethernet Slave

    OPC UA Server & MQTT ClientRaw Ethernet (NDIS)TCP socket interfaceIntegrated WebServerIntegrated WebServer

    JSON - Integration for

    IO-Link

    NTP-Client

    Pairing-Service

    Scan-Service Controlled roaming Blacklisting mechanism Frequency-Hopping Blacklisting mechanism

    Firmware-Update Over The Air

    NFD-3090-PNS-IOLM\W

    (tick)

    PROFINET IO

    (tick)(minus)(tick)(tick)(tick)(tick)(tick)(minus)(tick)(tick)(tick)
    NFD-3090-EIS-IOLM\W

    (tick)

    EtherNet/IP

    (tick)(minus)(tick)(tick)(tick)(tick)(tick)(minus)(tick)(tick)(tick)


    Note:

    Protocol support

    • NTP-Client - Network Time Protocol for time sychronisation
      a) Used for time stamping via OPC-UA
    • IO-Link JSON - REST API via TCP/IP

      a) for data access to IO-Link Masters, Ports and Devices and the Gateway.

      b) for IODD file management (up/download).

      c) for MQTT client configuration.

    IO-Link Wireless Feature Description

    • Pairing-Service: Pair devices with the appropriate master
    • Scan-Service: Add “un-paired” devices to the system
    • Controlled roaming of devices between diff erent masters
    • Frequency-Hopping to switch to free, unused frequency bands
    • Blacklisting mechanism to ensure the co-existence with other wireless systems
    • Firmware-Update Over The Air - for IO-Link W-Device and W-Bridges
    Panel
    bgColor
    Section
    Column
    width50%

    General

    • First Release Version
    Column
    width50%
    #ffffff
    titleBGColorlightgrey
    title
    Changes in this version
    Radio Approvals

    RED - Richtlinie 2014/53/EU

    Radio equpiment directive

    Area: Europe incl. EFTA states

    FCC Identification number

    Federal Communications Commission

    Area: United States of America

    ISED certification label

    Innovation, Science and Economic Development Canada

    Area: Canada

    netFIELD IO-Link Wireless Master

    (tick)

    2ANEG-0002

    (in preparation)

    24152-0002

    (in preparation)

    User manual netFIELD IO-Link Wireless Master EtherNet/IP Adapter

    250

    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleDocumentation

    Page Properties Report

    section

    firstcolumn

    column

    Page

    width

    spaces

    50%

    User manual netFIELD IO-Link Wireless Master PROFINET IO-Device

    View file
    namenetFIELD IO-Link Wireless NFD-3090-PNS-IOLM_W UM 02 EN.pdf
    height250

    Column
    width50%
    View file
    namenetFIELD IO-Link Wireless NFD-3090-EIS-IOLM_W UM 02 EN.pdf
    height
    DL
    headingsDocument type, Document title, Content, Date, Language, File type
    labelnetx51_documentation_current_release
    reverseSorttrue
    cqllabel in ("doc201101um02en","doc200701um02en") and space = "DL"

    Panel
    bgColor#ffffff
    titleBGColorlightgrey
    titleDownloads

    Device Description (~80 KByte): DeviceDescription_netFIELD_Device_IO-Link_Wireless_Master_DVD_2021-09-1

    Firmware & EDS (~4 MByte): Firmware_netFIELD_Device_IO-Link_Wireless_Master_DVD_2021-09-1

    Full Download (~10 MByte): Full_netFIELD_Device_IO-Link_Wireless_Master_DVD_2021-09-1

     Return to overview page...