Section | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Technical Data
Feature | Description | |||
---|---|---|---|---|
Maximum number of total cyclic input data | 244 bytes | |||
Maximum number of total cyclic output data | 244 bytes | |||
Maximum number of acyclic read/write | 240 bytes | |||
Configuration data | Max. 244 bytes | |||
Parameter data | 237 bytes application specific parameters | |||
Acyclic communication | DP V1 Class 1 Read/Write DP V1 Class 1 Alarm DP V1 Class 2 Read/Write/Data Transport | |||
Baud rate | Fixed values ranging from 9,6 kBits/s to 12 MBit/s Auto-detection mode is supported | |||
Data transport layer | PROFIBUS FDL |
Configuration
Configuration is done by sending packets to the stack transfer config parameters or by using SYCON.net configuration database.
Diagnostic
...
...
Firmware supports common and extended diagnostic in the dual-port-memory for loadable firmware.