Release Notes
Status

BETA      

Release Date

 

Version1.0.0.0
Summary
  • First BETA Version for evaluation purpose

Note: We reserve the right to make technical changes without prior notice.

netFIELD Device IO-Link Wireless Master - Business Model

Direct Selling - Preloaded communication module

The Device is sold as a product directly by Hilscher HQ, by the distributors and by the subsidiaries.


You can use netRAPID 90 as companion solution in the style of a communication module to be connected with a host CPU.

In this scenario, netRAPID 90 comes preloaded with a communication protocol and is ready to use.

For the companion solution, no netX licence or support contracts are required.

In the preloaded version, the pin assignment is fixed to certain functionality:

  • Real-Time Ethernet or Fieldbus Slave
  • SPI interface to the host CPU
  • LEDs (COM0, COM1, Link/Activity 0/1)
  • SYNC0/1
  • UART Diagnosis
  • +3.3V, GND

Standalone Solution - Programming platform like a netX90 chip

You can use netRAPID 90 in a stand-alone solution without any host.

This use case can be considered as nearly identical to the direct use of a netX 90 chip.

The pin assignment is flexible and can be adapted by the customer according to his or her needs by using the tool netX Studio CDT.

For this approach, a netX license and support agreement as well as the purchase of appropriate protocol stacks are required.

In this scenario, the netRAPID 90 is provided as a pure hardware-platform.


Option:

To reduce production costs at the OEM, Hilscher optionally offers the service to supply netRAPID 90 preloaded with customer specific content.

For further details about this service please contact the Hilscher sales team.


Getting Started
StepDescrition

Requirements and preparation

  • Prepare the device installation and commissioning according to the requirements descriptions on hardware, system and software.
  • Prepare the required mounting tools.

Safety

  • Read the mounting instructions and the safety instructions on connecting and commissioning the device.
  • Disconnect the system to which the device will be mounted from the power supply.

Mounting

  • Mark the positions to fasten the device with screws and cut the M4 holes.
  • Fasten the device with the screws.
  • Ground the device.
  • Mount all three SMA antennas.

Connecting and booting

  • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
  • Connect the +24 V DC SELV or PELV power supply to the sensor/actuator.
  • Switch on the power supply units of the device and of the sensors/actuators.
Commissioning PROFINET IO Device
  • Configure the PROFINET IO-Controller: Import the GSDML file:
    GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-20200624.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
    GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-NOCONFIG-20200624.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
  • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
  • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
  • Configure the IO-Link sensors/actuators.

Commissioning EtherNet/IP Adapter

  • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
  • Configure the EtherNet/IP Scanner: Import the EDS file:
    HILSCHER_NETFIELD_V1.1_IOL_W.EDS
  • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
  • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
  • Configure the IO-Link sensors/actuators.


Components - Tools
Components - Firmware
Configuration Tool

Communication Studio - Tool to create a network configuration and to download to the device.

Operating SystemWindows 8Windows 8.1Windows 10
Status(tick)

(Haken)

(Haken)

Configuration Tool

Device Library - Library with all Hilscher devices for the Communication Studio

Operating SystemWindows 7Windows 8Windows 8.1Windows 10
Status(tick)(tick)

(Haken)

(Haken)
Configuration Tool

Device Explorer - Tool to load a communication firmware to a hardware target.

Operating SystemWindows 7Windows 8Windows 8.1Windows 10
Status(tick)(tick)

(Haken)

(Haken)
netX Development with Eclipse

netX Studio Engineering CDT (netX Development with Eclipse) - Tool to create a Flash Device Label (FDL), Hardware Config File (HWC) and application for netX90 based devices.

Operating System Windows 2000Windows XP SP3Windows Vista SP2Windows 7Windows 8Windows 8.1Windows 10
Status(Fehler)(error)(error)

(Haken)

(Haken)

(Haken)

(Haken)
Supported Hardware and Protocols

CC-Link

Slave

CANopen

Slave

DeviceNet

Slave

PROFIBUS-DP

Slave

CC-Link IE Field Basic

Slave

EtherCAT

Slave

EtherNet/IP

Adapter

Modbus/TCP

Client/Server

POWERLINK

Controlled Node

PROFINET IO

Device

Sercos

Slave

VARAN

Client

optional

OPC UA / MQTT

optional

Security

optional

WebServer pages

NRP H90-RETBDTBDTBD(Haken)TBD(tick)(tick)TBDTBD(tick)TBDTBD(error)(error)(error)
NRP H90-RE\F8D8TBDTBDTBD(tick)TBD(tick)(tick)TBDTBD(tick)TBDTBDTBDTBD(tick)
Product Features
netRAPID types

Protocol support

(for more details, please see the Technology section)

Host interfaceDiagnostic interface

SYNC0/1


Memory OptionsIntegrated
magnetics

Real-Time Ethernet Slave

Fieldbus SlaveOPC UA Server
& MQTT Client
Raw Ethernet (NDIS)TCP socket interfaceIntegrated WebServerSPM

DPM

USBUARTSQI FLASHSDRAM
NRP H90-RE(tick)(tick)(error)(tick)(tick)

BASIC

(Haken)(error)(error)(tick)(tick)(error)(error)(error)
NRP H90-RE\F8D8(tick)(tick)(tick)(tick)(tick)(tick)(Haken)(error)(error)(tick)(tick)8 MByte8 MByte(error)


Note:

Depending on the available memory size (Internal RAM / Flash and external SDRAM / SQI Flash) different firmware functionality can be used.

  • Firmware for small footprint, low cost and function optimized slave devices
    Use Case A firmware for internal RAM / Flash only
  • Full featured firmware for highest function requirements
    Use Case C firmware which needs external SDRAM / SQI Flash

Details about the avaialble functionality can be found in the Technology section.


Host interface channel structure of NRP 51-RE


Channel 0: Real-Time Ethernet or Fieldbus Slave (Cyclic & Acyclic I/O)

Channel 1: NDIS, TCP socket and Web Interace

Channel 2: IOT communication as future option


Note1: At netRAPID90 All 3 channel can be can only be accessed in SPM host interface mode.

Note2:  netRAPID 90 owns 4 MAC addresses (MAC0 to MAC3), which will be provided per default from the Hilscher MAC address pool.

            MAC0 will be used for RTE communication in channel 0. MAC1 and MAC2 are reserved for Real-Time Ethernet. MAC3 will be used for Raw Ethernet.

            TCP socket in channel 1 and future IoT communication in channel 2 will use the same MAC0 and IP as the RTE communication.

            Raw Ethernet in channel 1 will use MAC3. IP address will be provided from the host application.


Changes in this version

General

  • First BETA Version for evaluation purpose
  • For Compantion Solution only

Specific functionality

  • For Companion Solution:
    • Communication Studio & Device Library for network Configruation
    • Device Explorer for Firmware download and device assignement
    • EtherNET Adpater firmware
    • USB - SPM host interface driver
    • UART diagnostic
  • For Standalone solution
    • netXStudio CDT - not implemented yet
    • USB - JTAG driver - not implemented yet
Documentation

User manual netFIELD IO-Link Wireless Master PROFINET IO-Device

User manual netFIELD IO-Link Wireless Master EtherNet/IP Adapter

 Return to overview page...


  • No labels