Q

I've just updated the LFW as well as MFW, after SET_CONFIGURATION_REQ packet is sent, netX90 returns with an ERR_HIL_FIRMWARE_STARTUP_ERROR (0xC0000129), what could be the problem?

A

If it's use case C, please check first, if the LFW version is compatible with MFW version:
Which Maintenance Firmware is compatible to which protocol firmware (netX90 Use Case C)?

Maintenance Firmware(MFW) V1.3.0.0 and higher version has Flash Translation Layer (FTL) intergated, which is incompatible to earlier versions, so a full format request (HIL_FORMAT_REQ) is required in this case when the MFW is downloaded to INTFALSH01 and run for the first time. The full format takes about 1 or 2 minutes, and the SYS led will blinks green druing the period.

If an ERR_HIL_FIRMWARE_STARTUP_ERROR (0xC0000129) returns not caused by flash file system(FFS) issue, then it could be something wrong with the hardware configuration file(*.hwc). Please check the configuration of your hardware config file(*.xml), and "Build Hardware Configuration..." with the latest netX Studio CDT tool, which integrates the current version of the hardware config tool.
https://kb.hilscher.com/display/NDT

Sometimes, the ERR_HIL_FIRMWARE_STARTUP_ERROR returns, if the uart firewall is not set correctly. E.g. If you set APP has read/write access, then you must disable uart 0 of LFW via taglist editor.