Setup netFIELD Device via Lauterbach Scripts
Gordon Göhrmann
How to Setup netFIELD Device via Lauterbach Scripts?
In order to setup a netFIELD Device, several files and images have to be written to the netX90 flash areas. For this purpose, the Lauterbach debugger in combination with scripts can be used.
With exception of the filesystem image, correct offsets, sizes and areas should be preset in flasher dialogue after the file has been selected.
Attach to netFIELD-Device
Attach to netX90-COM via Targets - netX90 - Attach - Attach COM
Stop and Reset System if Device is running
Select File to be Flashed to netFIELD Device
Select File via Flasher - Flasher
Hardware Configuration
Select Hardware Configuration File (*.HWC) and write to IFLASH01 area
Offset: 0
Size: 0x2000
Device Label
Select Flash Device Label and write to IFLASH01 area
Offset: 0x2000
Size: 0x1000
The Flash Device Label contains 1KB Production Data and a 3KB netFIELD specific taglist
netFIELD Firmware for netx90 COM
Select netFIELD COM Firmware (*.nxi) and write to IFLASH01 area
Offset: 0x3000
Size: 0xFFFFFFFF
Maintenance Firmware
Select Maintenance Firmware for netX90 with filesystem and write to IFLASH01 area
Offset: 0xE1000
Size: 0x1F000
Hardware Configuration for the Maintenance Firmware
Select the Hardware configuration for the maintenance firmware (*.mwc) and write to IFLASH01 area
Offset: 0xDF000
Size: 0x2000
netFIELD Continuous Firmware for netx90 COM
Select netFIELD COM continuous firmware (*.nxe) and write to SQI area
Offset: 0
Size: 0xFFFFFFFF
netFIELD Firmware for netx90 APP
Select netFIELD application firmware (*.nai) and write to IFLASH2 area
Offset: 0
Size: 0xFFFFFFFF
Filesystem Image
Select a proper filesystem image and write to SQI area
Offset: 0x100000
Size: 0xFFFFFFFF
Filter by label
There are no items with the selected labels at this time.