Setup netFIELD Device via Lauterbach Scripts

Q

How to Setup netFIELD Device via Lauterbach Scripts?

A

In order to setup a netFIELD Device, several files and images have to be written to the netX90 flash areas. For this purpose, the Lauterbach debugger in combination with scripts can be used.

With exception of the filesystem image, correct offsets, sizes and areas should be preset in flasher dialogue after the file has been selected.

Attach to netFIELD-Device

Attach to netX90-COM via Targets -  netX90 - Attach - Attach COM

Stop and Reset System if Device is running


Select File to be Flashed to netFIELD Device

Select File via Flasher - Flasher

Hardware Configuration

Select Hardware Configuration File (*.HWC) and write to IFLASH01 area

Offset: 0
Size: 0x2000

Device Label

Select Flash Device Label and write to IFLASH01 area

Offset: 0x2000
Size: 0x1000

The Flash Device Label contains 1KB Production Data and a 3KB netFIELD specific taglist

netFIELD Firmware for netx90 COM

Select netFIELD COM Firmware (*.nxi) and write to IFLASH01 area

Offset: 0x3000
Size: 0xFFFFFFFF

Maintenance Firmware

Select Maintenance Firmware for netX90 with filesystem and write to IFLASH01 area

Offset: 0xE1000
Size: 0x1F000

Hardware Configuration for the Maintenance Firmware

Select the Hardware configuration for the maintenance firmware (*.mwc) and write to IFLASH01 area

Offset: 0xDF000
Size: 0x2000

netFIELD Continuous Firmware for netx90 COM

Select netFIELD COM continuous firmware (*.nxe) and write to SQI area

Offset: 0
Size: 0xFFFFFFFF

netFIELD Firmware for netx90 APP

Select netFIELD application firmware (*.nai) and write to IFLASH2 area

Offset: 0
Size: 0xFFFFFFFF

Filesystem Image

Select a proper filesystem image and write to SQI area

Offset: 0x100000
Size: 0xFFFFFFFF

See also...

Filter by label

There are no items with the selected labels at this time.