netFIELD Device IO-Link Wireless Master DVD 2022-02-1

Release Notes
Status

RELEASED      

Release Date

 

Version1.1.0.0
Summary

Release with support of PROFINET IO Device, EtherCAT Slave and EtherNet/IP Adapter including OPC-UA Server and MQTT Client.

Note: We reserve the right to make technical changes without prior notice.


Getting Started

First Steps

For a detailed instruction how to set up your netFIELD Device IO-Link Wireless Master, please follow the chapter "Getting Started" in the User Manual.

→ …\Documentation\User_Manuals\...

Mounting

  • Mark the positions to fasten the device with screws and cut the M4 holes.
  • Fasten the device with the screws.
  • Ground the device.
  • Mount all three SMA antennas.

Connecting and booting

  • Connect the Ethernet M12 cable to the NFD-3090-PNS-IOLM\W device and to the PLC (PROFINET IO-Controller).
  • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-PNS-IOLM\W device
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
  • Connect the +24 V DC SELV or PELV power supply to the IO-Link Device.
  • Switch on the power supply units of the device and of the IO-Link Device.

Commissioning PROFINET IO Device

  • Configure the PROFINET IO-Controller: Import the GSDML file:
    ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-EXPERT-20210707.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
     ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-PDCT-20210623.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
  • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
  • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
  • Configure the IO-Link Device.

Commissioning EtherCAT Slave

  • For the first commissioning, the NFD-3090-ECS-IOLM\W device requires a DHCP server.
  • In the configuration software of the EtherCAT Master:
    • Configure the EtherCAT Master: Import the EDS file:
      ...\Firmware_&_EDS\DeviceDescription\EtherCAT\... Hilscher_netFIELD_Wireless.xml.
    • Create the configuration project with EtherCAT Master and EtherCAT Slave, select the modules and submodules and set the parameters.
  • For the subsequent steps the following configuration tools can be used:
    • Configure the IO-Link Wireless Master NFD-3090-ECS-IOLM\W using the netFIELD Wireless Web Server.
    • Configure the wireless IO-Link port parameters via the configuration software of the EtherCAT Master or using the netFIELD Wireless Web Server.
    • Configure the IO-Link Device.

Commissioning EtherNet/IP Adapter

  • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
  • Configure the EtherNet/IP Scanner: Import the EDS file:
    ...\Firmware_&_EDS\DeviceDescription\EtherNetIP\... HILSCHER-NETFIELD-WIRELESS-V2.1.EDS
  • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
  • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
  • Configure the IO-Link Device.

Documentation

Documentation for all hard- and software components included in this Product DVD is available on the path: …\Documentation\...

The Documentation Library on the Hilscher Knowledgebase includes further documents: https://hilscher.atlassian.net/wiki/display/DL/Documentation+Library+Home

Support

In case of questions, please do not hesitate to get in touch with your local Hilscher Support.       

E-Mail: support@hilscher.com

Phone: +49 6190 9907 99


Firmware & EDS

Product Update Firmware

Version

Description

netFIELD Device IO-Link Wireless Master 

  • PROFINET IO Device
  • EtherCAT Slave
  • EtherNet/IP Adapter
V2.2.0.5

Product Update Integration Firmware:

  • netFIELD Device Application layer firmware
  • netFIELD Device Communication protocol incl. IO-Link Wireless Master firmware
  • netX 90 Maintenance firmware - standalone firmware for system recovering and download functions

Supported Protocols

CC-Link IE Field Basic

Slave

EtherCAT

Slave

EtherNet/IP

Adapter

Modbus/TCP

Client/Server

POWERLINK

Controlled Node

PROFINET IO

Device

Sercos

Slave

VARAN

Client

netFIELD IO-Link Wireless Master

(minus)

(tick)

(tick)(minus)(minus)(tick)(minus)(minus)
Product Features
netFIELD IO-Link Wireless types

Protocol support

IO-Link Wireless support


Real-Time Ethernet Slave

OPC UA ServerMQTT ClientIntegrated WebServer

JSON - Integration for

IO-Link

NTP-Client

Pairing-Service

Scan-Service Blacklisting mechanism

Firmware-Update Over The Air

NFD-3090-PNS-IOLM\W

(tick)

PROFINET IO

(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
NFD-3090-ECS-IOLM\W

(tick)

EtherCAT

(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
NFD-3090-EIS-IOLM\W

(tick)

EtherNet/IP

(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)


Note:

Protocol support

  • NTP-Client - Network Time Protocol for time sychronisation
    a) Used for time stamping via OPC-UA
  • MQTT Client
    a) Publication of information about identification, capabilities, configuration and connection status to the IO-Link Master and Devices with MQTT objects
  • IO-Link - JSON integration
    a) Data access to IO-Link Masters, Ports and Devices and the Gateway.
    b) Accesible via REST API (TCP/IP)

IO-Link Wireless Feature Description

  • Pairing-Service: Pair devices with the appropriate master
  • Scan-Service: Add “un-paired” devices to the system
  • Blacklisting mechanism to ensure the co-existence with other wireless systems
  • Firmware-Update Over The Air - for IO-Link W-Device and W-Bridges
Radio Approvals

RED - Richtlinie 2014/53/EU

Radio equpiment directive

Area: Europe incl. EFTA states

FCC Identification number

Federal Communications Commission

Area: United States of America

ISED certification label

Innovation, Science and Economic Development Canada

Area: Canada

netFIELD IO-Link Wireless Master

(tick)

(tick)

2ANEG-0002

(tick)

24152-0002

Documentation

 Return to overview page...