PROFINET IO-Device V5.5.0.9

Release notes summary


Firmware Generation Status

ACTIVELATEST

Remarkrecommended for new projects
AvailabilitynetX 90 (tick)

Type

HOTFIX

Maintenance Status

MAINTAINED

Date2024-07-18
Summary
  • fix issue with SinglePort firmware sometimes reporting wrong value for LineDelay (which is not supported and should always be reported as 0)
  • fix issue with EthernetInterface API (NDIS mode) for SinglePort firmware that unexpectedly modified Source MAC Address of frames sent to network
  • fix wrong statements about netload for SinglePort firmware in GSDML and technical datasheet
Maintenance Firmware
  • netX90 Usecase C requires Maintenance Firmware V1.3.0.0 or newer
  • netX90 Usecase A is compatible to Maintenance Firmware V1.1.0.x or newer
Note(warning) Starting with firmware version V5.5.0.0, the firmware requires netX 90 with date code 1910 and later.
If a NXHX 90-JTAG is used, hardware revision 4 or higher is required. netX 90 samples (date code before 1910)
are no longer supported which is the case for NXHX 90-JTAG hardware revision 3 or lower.
Certification relevant issues

Getting issues...

Certification info

PNIO_Version: 2.43 (but only ConformanceClass A-C)

Intended TestBundle for this version of Protocol stack:

TestBundle VersionStateReleasedateLast day to request certification
according to this testbundle
Last day for testing
according to this testbundle
2.43 (August 2022)

OBSOLETE

 

  