InxPROFIdrive V1.2
Changes in v1.2 since v1.1
--------------------------
- Support PROFIdrive specific data types
- Fixed Fault situations acknowledgement
- added missing check for faulty parameter Description (Low/High Limit and reference Parameter)
- Fixed swap parameter value when an Octet element is requested
Changes in v1.1 since v1.0
--------------------------
- Updated to errata List:
- Added Error codes Illegal Request (0x21) and Request Block too long (0xB1) (Errata item 18 and 32)
- Defined Error (to much parameter requested) 0x22 if the number of permissible requested parameters is exceeded (Errata item 34)
- Fixed handling of String Parameters (Errata item 36)
- Fixed number of parameter in case of negative Response (Errata item 41)
- Extended Parameter Request/Response block sizes (up to 1024 Block)
- Updated Host application and Profile resources
- Added handling of V2 Data type
- Fixed Parameter text handling
- Added handling of Parameters P61000 to P610004 (PROFINET specific Parameters)
- Implemented handling to create a Parameter block
- Added the complete and optional Fault Buffer configuration
- Implemented handling to register a parameter for notification services
- Added support for I&M Record
------------------
Reihenfolge: type, key, summary, fixversion, status, resolution