Features
Key Features
- Phase control
- Service channel
- Procedure command
- Ring healing control
- Bus scan
- NRT channel
- Hot plug
Supported Protocols
- Sercos specification V1.3
On this page
Technical Data
Feature | Description |
---|---|
Maximum number of cyclic input data | 5760 bytes (including Connection Control per Connection) |
Maximum number of cyclic output data | 5760 bytes (including Connection Control per Connection) |
Maximum number of configured slave devices | 511 |
Acyclic communication | Service channel: Read/Write/Commands |
Functions | Bus Scan |
Topology | Line and double ring |
Redundancy supported | Yes |
Baud rate | 100 MBit/s, full duplex |
Data transport layer | Ethernet II, IEEE 802.3 |
Auto crossover | Supported |
Supported sercos version | Communication Specification Version 1.3 |
Hot Plug | Yes (since V2.1.4.0) |
Configuration
Configuration by packets to transfer bus parameters and slave configuration data or by using SYCON.net configuration database.
Diagnostic
Firmware supports common and extended diagnostic in the dual-port-memory for loadable firmware.