Skip to end of banner
Go to start of banner

PDO Upload

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

nota bene: in order to be able to use this feature, Hilscher EtherCAT Master Firmware V4.4.0.1 or newer shall be used..

In SYCON.net, after a successful network scan od manual offline configuration of EtherCAT Slaves:

  • the bus state shall Pre-Operational or Operational
  • set the Slave DTM online (menu Connect)
  • With the feature online parameterization (menu Configuration → Online Parameterize) CoE objects can be uploaded:
    • SDO, Device idents,
    • process data configuration
    • see the screenshots below:


    • The dialog Online Parameterize


    • SDO Upload


    • PDO Upload.

      Perform "Synchronize" in order to use the Device Data (uploaded PDOs) for the device configuration in the DTM /SYCON.net).
  • No labels