netFIELD Device IO-Link Wireless Master DVD 2021-09-1

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 10 Next »

Release Notes
Status

BETA      

Release Date

 

Version1.0.0.0
Summary
  • First Release with support of PROFINET IO Device, EtherNet/IP Adapter including OPC-UA Server and MQTT Client

Note: We reserve the right to make technical changes without prior notice.


Getting Started

Mounting

  • Mark the positions to fasten the device with screws and cut the M4 holes.
  • Fasten the device with the screws.
  • Ground the device.
  • Mount all three SMA antennas.

Connecting and booting

  • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
  • Connect the +24 V DC SELV or PELV power supply to the sensor/actuator.
  • Switch on the power supply units of the device and of the sensors/actuators.

Commissioning PROFINET IO Device

  • Configure the PROFINET IO-Controller: Import the GSDML file:
    GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-20200624.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
    GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-NOCONFIG-20200624.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
  • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
  • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
  • Configure the IO-Link sensors/actuators.

Commissioning EtherNet/IP Adapter

  • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
  • Configure the EtherNet/IP Scanner: Import the EDS file:
    HILSCHER_NETFIELD_V1.1_IOL_W.EDS
  • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
  • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
  • Configure the IO-Link sensors/actuators.

Documentation

Documentation for all hard- and software components included in this Product DVD is available on the path: …\Documentation\...

The Documentation Library on the Hilscher Knowledgebase includes further documents: https://kb.hilscher.com/display/DL/Documentation+Library+Home

Support

In case of questions, please do not hesitate to get in touch with your local Hilscher Support.       

E-Mail: support@hilscher.com

Phone: +49 6190 9907 99


Download


Supported Protocols

CC-Link IE Field Basic

Slave

EtherCAT

Slave

EtherNet/IP

Adapter

Modbus/TCP

Client/Server

POWERLINK

Controlled Node

PROFINET IO

Device

Sercos

Slave

VARAN

Client

netFIELD IO-Link Wireless Master

(error)(error)(Haken)(error)(error)(Haken)(error)(error)
Product Features
netFIELD IO-Link Wireless types

Protocol support

(for more details, please see the Technology section)

IO-Link Wireless support


Real-Time Ethernet Slave

OPC UA Server
& MQTT Client
Raw Ethernet (NDIS)TCP socket interfaceIntegrated WebServer

Pairing-Service

Scan-Service

Controlled roaming

Frequency-Hopping Blacklisting mechanism
NFD-3090-PNS-IOLM\W

(tick)

PROFINET IO

(tick)(minus)(tick)(tick)(tick)(tick)(minus)(tick)(tick)
NFD-3090-EIS-IOLM\W

(tick)

EtherNet/IP

(tick)(minus)(tick)(tick)(tick)(tick)(minus)(tick)(tick)


Note:

IO-Link Wireless Feature Description

  • Pairing-Service: Pair devices with the appropriate master
  • Scan-Service: Add “un-paired” devices to the system
  • Controlled roaming of devices between diff erent masters
  • Frequency-Hopping to switch to free, unused frequency bands
  • Blacklisting mechanism to ensure the co-existence with other wireless systems
Changes in this version

General

  • First Release Version

Specific functionality

  • Industrial Ethernet
    • PROFINET IO Device
    • EtherNet/IP Adapter
  • Diagnosis infaces
    • OPC-UA Server
    • MQTT Client
  • IO-Link Wireless Master
    • Supports up to 16 Wireless IO-Link Device simultaneously via two parallel transmission tracks
    • Scan mode, simple pairing of discoverable IO-Link devices
    • Wireless range of point-to-point communication up to 10 meter
  • Robust IP67 design
Documentation

User manual netFIELD IO-Link Wireless Master PROFINET IO-Device

User manual netFIELD IO-Link Wireless Master EtherNet/IP Adapter

 Return to overview page...