FeatureDescription
Maximum number of input data504 bytes per assembly instance
Maximum number of output data504 bytes per assembly instance
IO Connection Types (implicit)

Exclusive Owner, Listen Only,

Input only
IO Connection Trigger Types

Cyclic, minimum 1 ms*
Application Triggered, minimum 1 ms*
Change Of State, minimum 1 ms*

Explicit MessagesConnected and unconnected
Max. number of connections8 (sum of connected explicit and implicit connections)
Max. number of user specific objects20
Unconnected Message Manager (UCMM)supported
Predefined standard objects

Identity Object (0x01)
Message Router Object (0x02)
Assembly Object (0x04)
Connection Manager (0x06)
DLR Object (0x47)
QoS Object (0x48)
TCP/IP Interface Object (0xF5)
Ethernet Link Object (0xF6)

DHCPsupported
BOOTPsupported
Baud rates10 and 100 MBit/s
Duplex modesHalf Duplex, Full Duplex, Auto-Negotiation
MDI modesMDI, MDI-X, Auto-MDIX
Data transport layerEthernet II, IEEE 802.3
Address Conflict Detection (ACD)supported
DLR V2 (ring topology)supported
Quick Connectsupported
Integrated switchsupported
CIP Reset servicesIdentity Object Reset Service of Type 0 and 1

...