Key Features
- Device Level Ring (DLR) - Media Redundancy
- Address Conflict Detection (ACD)
- Quick Connect (Fast Startup)
- Connection Classes: 0, 1, 3
- Connection Application Types: Exclusive Owner, Input Only, Listen Only Connections
- Explicit Messaging
- Quality of Service
- Object model can be extended by implementing own CIP objects (necessary to support CIP profiles)
- CIP Sync
Supported Protocols
- TCP/IP, UDP/IP
- DLR
- DHCP / BOOTP
- IEEE 802.3
- IEEE 802.1Q
On this page
Technical Data
Feature | Description |
---|---|
Maximum number of input data | 504 bytes per assembly instance |
Maximum number of output data | 504 bytes per assembly instance |
IO Connection Types (implicit) | Exclusive Owner, Listen Only, Input only |
IO Connection Trigger Types | Cyclic, minimum 1 ms* |
Explicit Messages | Connected and unconnected |
Max. number of connections | 8 (sum of connected explicit and implicit connections) |
Max. number of user specific objects | 20 |
Unconnected Message Manager (UCMM) | supported |
Predefined standard objects | Identity Object (0x01) |
DHCP | supported |
BOOTP | supported |
Baud rates | 10 and 100 MBit/s |
Duplex modes | Half Duplex, Full Duplex, Auto-Negotiation |
MDI modes | MDI, MDI-X, Auto-MDIX |
Data transport layer | Ethernet II, IEEE 802.3 |
Address Conflict Detection (ACD) | supported |
DLR (ring topology) | supported |
Quick Connect | supported |
Integrated switch | supported |
CIP Reset services | Identity Object Reset Service of Type 0 and 1 |
Configuration
Configuration is done by sending packets to the stack or by using SYCON.net configuration database.
Diagnostic
The stack supports common diagnostic in the dual-port-memory for loadable firmware.