Skip to end of banner
Go to start of banner

Download package IO-Link Wireless Master 2022-05-05

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 15 Current »

Release Notes
Status

RELEASE

Release Date

 

Version1.2.0.0

Summary

Release with support of PROFINET IO Device, EtherCAT Slave and EtherNet/IP Adapter including OPC-UA Server and MQTT Client.

Contains IO-Link ET application for configuration of the IO-Link Wireless Masters from Hilscher and connected IO-Link devices.

Note: We reserve the right to make technical changes without prior notice.


Getting Started

Software Installation

 Software Installation - IO-Link

Configuration Tool IO-Link ET

Install IO-Link ET on your computer to configure IO-Link Masters NFD-6090-xxx-IOLMA\M12 and NFD-3090-xxx-IOLM\W and connected IO-Link Devices.

(xxx means PNS for PROFINET IO, EIS for EtherNet/IP and ECS for EtherCAT)

→ …\Software_&_Tools\IO-Link_ET\...

First Steps

 Click here to expand...

For a detailed instruction how to set up your netFIELD Device IO-Link Wireless Master, please follow the chapter "Getting Started" in the User Manual.

→ …\Documentation\User_Manuals\...

Mounting

  • Mark the positions to fasten the device with screws and cut the M4 holes.
  • Fasten the device with the screws.
  • Ground the device.
  • Mount all three SMA antennas.

Connecting and booting

  • Connect the Ethernet M12 cable to the NFD-3090-PNS-IOLM\W device and to the PLC (PROFINET IO-Controller).
  • Connect the Ethernet M12 cable to the NFD-3090-EIS-IOLM\W device and to the PLC (EtherNet/IP Scanner).
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-PNS-IOLM\W device
  • Connect the +24 V DC SELV or PELV power supply to the NFD-3090-EIS-IOLM\W device.
  • Connect the +24 V DC SELV or PELV power supply to the IO-Link Device.
  • Switch on the power supply units of the device and of the IO-Link Device.

Commissioning PROFINET IO Device

  • Configure the PROFINET IO-Controller: Import the GSDML file:
    ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-EXPERT-20210707.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the configuration software of the PROFINET IO-Controller.
     ...\Firmware_&_EDS\DeviceDescription\Profinet\... GSDML-V2.35-HILSCHER-NETFIELD-WIRELESS-PDCT-20210623.xml
    This file is to be used if settings of the „Wireless Master Parameters“ are made using the netFIELD Web Server.
  • Create the configuration project with PROFINET IO-Controller and PROFINET IO-Device, select the modules and submodules and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-PNS-IOLM\W using the Web Server.
  • Configure the port parameters via the PROFINET IO-Controller or using the Web Server.
  • Configure the IO-Link Device.

Commissioning EtherCAT Slave

  • For the first commissioning, the NFD-3090-ECS-IOLM\W device requires a DHCP server.
  • In the configuration software of the EtherCAT Master:
    • Configure the EtherCAT Master: Import the EDS file:
      ...\Firmware_&_EDS\DeviceDescription\EtherCAT\... Hilscher_netFIELD_Wireless.xml.
    • Create the configuration project with EtherCAT Master and EtherCAT Slave, select the modules and submodules and set the parameters.
  • For the subsequent steps the following configuration tools can be used:
    • Configure the IO-Link Wireless Master NFD-3090-ECS-IOLM\W using the netFIELD Wireless Web Server.
    • Configure the wireless IO-Link port parameters via the configuration software of the EtherCAT Master or using the netFIELD Wireless Web Server.
    • Configure the IO-Link Device.

Commissioning EtherNet/IP Adapter

  • For the first commissioning, the NFD-3090-EIS-IOLM\W device requires a DHCP server.
  • Configure the EtherNet/IP Scanner: Import the EDS file:
    ...\Firmware_&_EDS\DeviceDescription\EtherNetIP\... HILSCHER-NETFIELD-WIRELESS-V2.1.EDS
  • Create the configuration project with EtherNet/IP Scanner and EtherNet/IP Adapter, select the connection and set the parameters.
  • Configure the IO-Link Wireless Master NFD-3090-EIS-IOLM\W using the Web Server.
  • Configure the port parameters via the EtherNet/IP Scanner or using the Web Server.
  • Configure the IO-Link Device.

Documentation

Documentation for all hard- and software components included in this Download Package is available on the path: …\Documentation\...

The Documentation Library on the Hilscher Knowledgebase includes further documents: https://kb.hilscher.com/display/DL/Documentation+Library+Home

Support

In case of questions, please do not hesitate to get in touch with your local Hilscher Support.       

E-Mail: support@hilscher.com

Phone: +49 6190 9907 99


Documentation

The documentation can be downloaded at:


Firmware, EDS, Examples

Product Update Firmware

Version

Description

netFIELD Device IO-Link Wireless Master 

  • PROFINET IO Device
  • EtherCAT Slave
  • EtherNet/IP Adapter
V2.2.0.5

Product Update Integration Firmware:

  • netFIELD Device Application layer firmware
  • netFIELD Device Communication protocol incl. IO-Link Wireless Master firmware
  • netX 90 Maintenance firmware - standalone firmware for system recovering and download functions


Configuration Tool

IO-Link ET

VersionComponentsRelease DateLatest Release
V1.0.0IO-Link ET

 

V1.0.0 Build 7859
Operating System Windows 10macOS 10.11Linux
Status(tick)(tick)(tick)
System requirements
  • 32 bit
  • 64 bit
  • Apple M1
  • Intel chips
  • 64bit only
  • Ubuntu 18.04 and newer
  • Fedora 24 and newer
  • Debian 8 and newer


Hardware and Protocols
Industrial network
CC-Link IE Field Basic Slave(minus)
EtherCAT Slave(tick)
EtherNet/IP Adapter(tick)
Modbus/TCP Client/Server(minus)
POWERLINK Controlled Node(minus)
PROFINET IO Device(tick)
Sercos Slave(minus)
VARAN Client(minus)


Radio Approvals

RED - Richtlinie 2014/53/EU

Radio equpiment directive

Area: Europe incl. EFTA states

(tick)

FCC Identification number

Federal Communications Commission

Area: United States of America

ID: 2ANEG-0002

(tick)

ISED certification label

Innovation, Science and Economic Development Canada

Area: Canada

ID:24152-0002

(tick)


Product Download Package

  File Modified

  • No labels