nota bene: in order to be able to use this feature, Hilscher EtherCAT Master Firmware V4.4.0.1 or newer shall be used..

In SYCON.net, after a successful network scan or a manual offline configuration of EtherCAT Slaves:

  • the bus state shall Pre-Operational or Operational
  • set the Slave DTM online (menu Connect)
  • With the feature online parameterization (menu Configuration → Online Parameterize) CoE objects can be uploaded:
    • SDO, Device idents,
    • process data configuration
    • see the screenshots below:


    • The dialog Online Parameterize


    • SDO Upload


    • PDO Upload.

      Perform "Synchronize" in order to use the Device Data (uploaded PDOs) for the device configuration in the DTM /SYCON.net).