Features
Key Features
- Remote I/O Station (I/O points only)
- Remote Device Station (I/O points and words)
Configurable number of occupied stations (1-4)
- Configurable number of extension cycles (1, 2, 4 or 8)
- Configurable vendor code and model type
Supported Protocols
- Support of both (configurable):
- CC-Link Version 2.0 and
- CC-Link Version 1.11
On this page
Technical Data
The data below applies to the CC-Link firmware and stack version V2.7.x. The firmware/stack supports CC-Link Version 2.0 and 1.11
This firmware/stack has been written to meet the requirements outlined in the CC-Link specification Ver.2.00 BAP-05026-J.
Feature | Description |
---|---|
Data for firmware/stack working according to CC-Link Version 2.0 | |
Station Types | Remote device station, up to four occupied stations |
Maximum input data | 368 bytes |
Maximum output data | 368 bytes |
Input data remote device station | 112 bytes (RY) and 256 bytes (RWw) |
Output data remote device station | 112 bytes (RX) and 256 bytes (RWr) |
Extension cycles | 1, 2, 4, 8 |
Baud rates | 156 kBit/s, 625 kBit/s, 2500 kBit/s, 5 MBit/s, 10 MBit/s |
Data for firmware/stack working according to CC-Link Version 1.11 | |
Station Types | Remote I/O station, remote device station, up to 4 occupied stations |
Maximum input data | 48 bytes |
Maximum output data | 48 bytes |
Input data remote I/O station | 4 bytes (RY) |
Output data remote I/O station | 4 bytes (RX) |
Input data remote device station | 4 bytes (RY) and 8 bytes (RWw) per occupied station |
Output data remote device station | 4 bytes (RX) and 8 bytes (RWr) per occupied station |
Baud rates | 156 kBit/s, 625 kBit/s, 2500 kBit/s, 5 MBit/s, 10 MBit/s |
Configuration
Configuration by packet to transfer warm start parameters
Diagnostic
Firmware supports common and extended diagnostic in the dual-port-memory for loadable firmware