netIC DVD 2017-09-1

Release Notes
Status

RELEASED      

Date2017-09-13
VersionV1.0900.4.4564 (DVD 2017-09-1)
Summary
  • Firmware update with various hotfixes
    • All netIC: Changing the UART baud rate at run time
    • Sercos for NIC52: Write IDN S-0-1300.0.5 by SIII_SL_IDN_CMD_WRITE_REQ
Note
  • Since 2 years NIC 52-RE / -REFO has been introduced as compatible replacement for  NIC 50-RE / -REFO.
    Any new functionality will only be added to NIC 52-RE / -REFO.
    For new projects NIC 52-RE / REFO shall be used.
  • NIC 50-RE / -REFO cannot be certified according to PROFINET V2.3 and EtherNetIP CT14.
  • No new features or updates will be added to NIC 50-RE / -REFO anymore.

Note: We reserve the right to make technical changes without prior notice.


Components - Tools
Components - Firmware


Version                      Component                                                      Hardware platform       Used protocol library     Used servX library       
1.5.16.0CANopen Slave - ModbusRTUNIC 50-COSCOS V3.6.3.0-
1.5.16.0CC-Link Slave - ModbusRTUNIC 10-CCSCCS V2.9.2.0-
1.5.16.0DeviceNet Slave - ModbusRTUNIC 50-COSDNS V2.5.0.1-
1.5.16.0EtherCAT Slave - ModbusRTUNIC 50-REECS V2.5.34.0-
1.5.16.0EtherNet/IP Slave - ModbusRTUNIC 50-REEIS V2.7.14.0V1.3.4.0
1.5.16.0Open Modbus/TCP Stack - ModbusRTUNIC 50-REOMB V2.5.14.0V1.3.4.0
1.5.16.0POWERLINK Slave - ModbusRTUNIC 50-REPLS V2.1.50.0-
1.5.16.0PROFIBUS DP Slave - ModbusRTUNIC 50-DPSDPS V2.8.0.2-
1.5.16.0PROFINET IO Device - ModbusRTUNIC 50-REPNS V3.4.145.1V1.3.4.0
1.5.16.0Sercos Slave - ModbusRTUNIC 50-RES3S V3.1.35.0V1.3.4.0
1.5.16.0VARAN Client - ModbusRTUNIC 50-REVRS V1.0.4.0-
1.5.16.0PROFINET IO Device Fiber Optic - ModbusRTUNIC 50-REFOPNS V3.4.145.1-
Version                     Component                                                       Hardware platform        Used protocol library     Used servX library       
2.1.0.4EtherCAT Slave - ModbusRTUNIC 52-REECS V4.6.0.4-
2.1.0.4EtherNet/IP Slave - ModbusRTUNIC 52-REEIS V2.11.0.8V1.4.0.0
2.1.0.4Modbus/TCP Stack - ModbusRTUNIC 52-REOMB V2.6.0.1V1.4.0.0
2.1.0.4POWRLINK Controlled Node - ModbusRTUNIC 52-REPLS V3.2.0.0-
2.1.0.4PROFINET IO Device - ModbusRTUNIC 52-REPNS V3.11.0.5V1.4.0.0
2.1.0.5Sercos Slave - ModbusRTUNIC 52-RES3S V3.3.0.6V1.4.0.0
2.1.0.4PROFINET IO Device Fiber Optic - ModbusRTUNIC 52-REFOPNS V3.11.0.5-
Configuration Tool

netX Configuration Tool

Operating System Windows 2000Windows XP SP3Windows Vista SP2Windows 7Windows 8Windows 8.1Windows 10
Status(Fehler)(Haken)(Haken)(Haken)(Haken)

(Haken)

(Haken)
Supported Hardware and Protocols

Important Note: 

  • Since 2 years NIC 52-RE / -REFO has been introduced as compatible replacement for NIC 50-RE / -REFO.
    Any new functionality will only be added to NIC 52-RE / -REFO.
    For new projects NIC 52-RE / REFO shall be used.
  • NIC 50-RE / -REFO cannot be certified according to PROFINET V2.3 and EtherNetIP CT14.
  • No new features or updates will be added to NIC 50-RE / -REFO anymore.


CC-Link

Slave

CANopen

Slave

DeviceNet

Slave

PROFIBUS-DP

Slave

EtherCAT

Slave

EtherNet/IP

Adapter

Open Modbus/TCP

Client/Server

POWERLINK

Controlled Node

PROFINET IO

Device

Sercos

Slave

VARAN

Client

Note
NIC 10-CCS(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)-
NIC 50-COS(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)-
NIC 50-DNS(Fehler)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)-
NIC 50-DPS(Fehler)(Fehler)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)-
NIC 50-RE(Fehler)(Fehler)(Fehler)(Fehler)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)PROFINET V2.2

NIC 50-REFO(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Haken)(Fehler)(Fehler)

PROFINET V2.2

NIC 52-RE(Fehler)(Fehler)(Fehler)(Fehler)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Fehler)PROFINET V2.3
Replacement for NIC 50-RE.
NIC 52-REFO(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Haken)(Fehler)(Fehler)

PROFINET V2.3
Replacement for NIC 50-REFO


Product Features


Host interfaceDiagnostic interface
SYNC0/1
Integrated
Webserver
(servX)

NDIS

TCP socket
interface


Modbus

via UART

Modbus

via SPI

USBUART
CC-Link SlaveNIC 10-CCS(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)
CANopen SlaveNIC 50-COS(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)
DeviceNet SlaveNIC 50-DNS(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)
PROFIBUS-DP SlaveNIC 50-DPS(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)
EtherCAT SlaveNIC 50-RE / NIC 52-RE(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)
EtherNet/IP AdapterNIC 50-RE / NIC 52-RE(Haken)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Fehler)

Open Modbus/TCP Client/Server

NIC 50-RE / NIC 52-RE(Haken)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Fehler)

POWERLINK Controlled Node

NIC 50-RE / NIC 52-RE(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)

PROFINET IO Device

NIC 50-RE / NIC 52-RE(Haken)(Haken)(Fehler)(Haken)(Fehler) 1)(Haken)(Fehler)(Fehler)

Sercos Slave

NIC 50-RE / NIC 52-RE(Haken)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Fehler)
VARAN ClientNIC 50-RE(Haken)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)

Legend

1) SYNC0/1 available on NIC 52-RE only for certification purpose.

Changes in this version

General

  • Firmware update with various hotfixes
    • All netIC: Changing the UART baud rate at run time
    • Sercos for NIC52: Write IDN S-0-1300.0.5 by SIII_SL_IDN_CMD_WRITE_REQ

Specific functionality

  • PNS Firmware for NIC 52-RE to comply with October test tool
  • EIS Firmware for NIC 52-RE to comply with CT14 test tool

Known Issues

The following issues have been found during system test and stay unsolved on the current release:

PRODNETIC-219 - Web page for unauthorized access might confuse the user

NXCONFIGPROD-23 - Sercos: IP address is editable when disabled 

NXCONFIGPROD-24 - Sercos: "Invalid parameter" message with disabled IP configuration 

NXCONFIGPROD-25 - netIC: Wrong help page for "Modbus-RTU"

Documentation

 Return to overview page...