netRAPID DVD 2016-11-1
Operating System | Windows 2000 | Windows XP SP3 | Windows Vista SP2 | Windows 7 | Windows 8 | Windows 8.1 | Windows 10 |
---|---|---|---|---|---|---|---|
Status |
Operating System | Windows XP | Windows Vista | Windows 7 (KB3033929) | Windows 8/8.1 | Windows 10 | Windows 10 (>= 1607 Secure Boot) | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Driver Version | V1.0.0.0 | V1.0.0.0 | V1.0.0.0 | V1.2.3.0 | V1.3.0.0 | V1.3.0.0 | ||||||
Architecture | x86 | x64 | x86 | x64 | x86 | x64 | x86 | x64 | x86 | x64 | x86 | x64 |
Status |
For other operting systems or toolkit follow the link.
CC-Link Slave | PROFIBUS-DP Slave | EtherCAT Slave | EtherNet/IP Adapter | Modbus/TCP Client/Server | POWERLINK Controlled Node | PROFINET IO Device | Sercos Slave | VARAN Client | |
---|---|---|---|---|---|---|---|---|---|
NRP 10-DPS | |||||||||
NRP 10-CCS | |||||||||
NRP 52-RE |
Host interface | Diagnostic interface | SYNC0/1 1) | Integrated 2) Webserver (servX) | NDIS 3) | TCP socket 4) interface | ||||
---|---|---|---|---|---|---|---|---|---|
SPM | DPM | USB | UART 1) | ||||||
PROFIBUS-DP Slave | NRP 10-DPS | 1) | 1) | ||||||
CC-Link Slave | NRP 10-CCS | 1) | 1) | ||||||
EtherCAT Slave | NRP 52-RE | 1) | 1) | ||||||
EtherNet/IP Adapter | NRP 52-RE | 1) | 1) | 4) | |||||
Modbus/TCP Client/Server | NRP 52-RE | 1) | 1) | ||||||
POWERLINK Controlled Node | NRP 52-RE | 1) | 1) | 4) | |||||
PROFINET IO Device | NRP 52-RE | 1) | 1) | 4) | |||||
Sercos Slave | NRP 52-RE | 1) | 1) | ||||||
VARAN Client | NRP 52-RE | 1) | 1) |
Legend
1) Shared pins, means either SYNC 0/1 or Diagnostic UART can be used. SYNC 0/1 is activated as default. Can be changed via SSBL TAG-List.
2) If supported, the integrated WebServer is activated as default. Can be deactivated via Firmware TAG-List.
3) If supported, the NDIS functionality is deactivated as default. Can be activated via Firmware TAG-List. Even the NDIS functionality will internally be handeled in a second channel, physically only one channel can be accessed at netRAPID. This will have affect on the overall performance and the cycle times of the Real-Time Ethernet system.
4) LWIP TCP stack is used, which has a different API than the Hilscher TCP stack.
General
- Update of all Firmware versions
- Update of all Tool versions
Specific functionality
- NEW: SYCON.net version 1.4
- NEW: USB Diagnostic support for PROFINET I/O Device
- NEW: POWERLINK Controlled Node firmware for NRP 52-RE
- NEW: VARAN Client firmware for NRP 52-RE
The netRAPID Evaluation DVD comes with limited firmware versions, whith the restrictions mentioned below.
Unlimited firmware versions need to be puchased once with a simple end user license agreement.
PROFINET IO device - limited:
- Specified operating period of 1 hour
EtherCAT Slave - limited:
- Specified operating period of 1 hour
EtherNet/IP Adapter - limited:
- Specified operating period of 1 hour
Sercos Slave - limited:
- Specified operating period of 1 hour
Modbus/TCP - limited:
- Specified operating period of 1 hour
POWERLINK Controlled Node - limited:
- Specified operating period of 1 hour
VARAN client - limited:
- Specified operating period of 1 hour
CCLink Slave - limited:
- Slave Station Address: 32
- Station type: only Remote IO
- CC-Link Version: V1.1
- Fix 2 Byte In- and Output
PROFIBUS-DP Slave - limited:
- Network Station Address: 32
- 2 Byte Output and 2 Byte Input Modules
The following issues have been found during system test and stay unsolved on the current released:
PRODECSV4-112 - NRP 52 configuration by SYCON.net with 353 bytes input + output and more does not work
PRODECSV4-115 - Wrong LED state after evaluation time of limited firmware has expired
PRODSCS-136 - Big IO configuration is sometimes not activated after Channel Init
PRODSCS-137 - Application watchdog does not work after first timeout with packet configuration
PRODSCS-138 - Wrong LED state after evaluation time of limited firmware has expired
PRODPLSV3-80 - Possible crash with NRP 52-RE after Watchdog timeout and Channel Init
PRODPLSV3-81 - "_ltd" is missing in the name of limited firmware
PRODPLSV3-82 - Limited firmware does not clear COM flag after evaluation time has expired
PRODPLSV3-83 - NRP 52-RE does not refuse configuration with more than 800 bytes
PRODPLSV3-84 - Possible crash with NRP 52-RE using wrong IO size
SYCONNET-374 - Limit PLS netX 52 devices to 800 bytes IO size
Return to overview page...