Technical Data - V5
The following technical data applies to the latest available Release version. Technical data of older Release versions may be different
Protocol Technical Data
Feature | Description |
---|---|
Maximum number of total cyclic input data | 1440 bytes |
Maximum number of total cyclic output data | 1440 bytes |
State Machine | State machine according to EPL specification |
Object dictionary | CANopen-style object dictionary according to the EPL specification |
Acyclic data transfer | SDO Upload/Download |
Additional supported features | SDO over ASnd and UDP Slave-to-slave communication Cross-Traffic Multiplexing |
Baud rate | 100 MBit/s, half duplex |
Data transport layer | Ethernet II, IEEE 802.3 |
Ethernet Powerlink version | V2 |
Restrictions
Stack supports and handles only one network interface
Slave-to-slave communication: Max. 8 communicating slaves supported (Loadable firmware)
- NXLOM is not available, only LFW (Loadable firmware) is provided
- Only devices with two Ethernet Ports are supported (no loadable firmware for single port Ethernet provided)
The real-time protocol stack is fully integrated into a netX firmware for specific use case in order to provide a common set of netX firmware functions accross different protocol variants:
Firmware Variants | Use Case A | Use Case B | Use Case C |
---|---|---|---|
Use Case summary | netX90 COM CPU firmware for small footprint, low cost and function optimized slave devices
| same as Use Case A, but netX90 APP CPU
| full featured firmware for highest function requirements
|
netX support |
|
|
|
FW structure | |||
Host Interface | Dual Port Memory interface with following channels:
| ||
Diagnostic Interface | netX Diagnostic and Remote Access is supported via COM UART | ||
Integrated Flash File System | N/A | N/A | Power-fail safe flash file system on external SPI flash is used |
Remanent Data Storage | Power-fail safe storage of up to 16KB of protocol remanent data in netX90 internal flash | Power-fail safe storage of protocol remanent data in dedicated partition in extenal SPI flash. Size and position of remanent storage area shall be configured in FDL. | |
Device Data | device production data (Serial number, MAC address, production data etc.) shall be stored in FDL in netX90 internal flash | ||
Firmware Transfer | to netX flash file system located on external SPI Flash | ||
Firmware Update | Firmware check and installation supported through calling the Maintenance Firmware (netX 90/4000) | ||
|
|
| |
Configuration | by sending configuration packets to the firmware via Host Interface | ||
N/A | or by using Communication Studio configuration database file from local flash file system | ||
Integrated Basic Webserver | The basic web server has the following features:
| ||
Webserver extension | N/A | Basic web server is extended with functions that provide access to the content files on a local Flash file system (SQI Flash).
| |
Tag List Options | Firmware supports certain modification of the functionality via Tag List, in particular:
| ||
HW Sync Signal | supported via netX signal XC_TRIGGER0/1 | ||
Protocol Specific LED Indicators | Network specific status indicators with COM0 / COM1 LEDs:
| ||
Secure Boot | supported by POWERLINK Controlled Node V5.2.0.0and later, see Support of Secure Boot with netX90 for more details | ||
Limitations |
|
|