Restrictions - V3

Restrictions

  • Max. 2 connections: 1 for consumer and 1 for producer
  • Modifications of the Service-Channel Object Dictionary are volatile after reset (if resides on device)
  • Cross communication not supported yet
  • UCC Communication: Second DPM Channel (“Ethernet Interface Task”) is not available on all hardware
  • Clock parameters ulDTDivClk  (Contents of DTDivClk register) and ulDivClkLength  (DivClk Length) are no longer adjustable (since V3.1). ulDivClkLength is now always set to the fixed value 1 μs. In Div_Clk mode 0 it is not possible any more to configure aperiodic signals. ulConClkLength has now a maximum of 655350 ns.

Firmware Features

Feature

Integrated HTTP Server

Integrated
TCP/IP Stack

Integrated Diagnostic and Remote Access via

Target

Serial

USB

TCP

cifX

No

No

No

No

No

comX

Yes

Yes, but no packet interface via Dual-port memory

No

Yes

No

netJACK






netX 50

Yes

Yes

No

No

No

netX 100

Yes

Yes

No

No

No

netX 500

Yes

Yes

No

No

No

NXIO 50

No

No

No

No

No

NXIO 100

No

No

No

No

No

Features of the integrated HTTP Server

  • Firmware Identification
  • Firmware Update
  • Device Reset
On this page