Features - V4
Features - V4
Key Features
- Exchange of cyclic data
- CoE (CANopen over EtherCAT)
- FoE (File access over EtherCAT, not over sycon.net)
- CoE-Upload, CoE-Download
- Bus scan
- Emergency
- Slave diagnostic
Supported Protocols
- CoE (CANopen over EtherCAT)
SoE (Servo Drive Profile over EtherCAT)
- FoE (File access over EtherCAT)
- EoE (Ethernet over EtherCAT)
On this page
Technical Data
Feature | Description |
---|---|
Maximum number of cyclic input data | 5760 bytes |
Maximum number of cyclic output data | 5760 bytes |
Maximum number of supported slaves | Must lastly be determined |
Minimum bus cycle time | 250 microseconds |
Acyclic communication | CoE (CANopen over EtherCAT), CoE-Upload, CoE-Download max. 1500 bytes, |
Functions | Get OD List Get object description Get entry description Emergency Slave diagnostics |
Topology | Line or ring |
Baud rate | 100 MBit/s |
Data transport layer | Ethernet II, IEEE 802.3 |
Size of configuration file (ethercat.xml or config.nxd) | Max. 1 MByte |
Bus Scan | Supported |
Redundancy | Supported |
Configuration
Two kinds of configuration are possible:
- Configuration by tool SYCON.net
By XML file generated by the “EtherCAT Configurator” available from the ETG or by TwinCAT IO tool available from Beckhoff. In this case, the name of the configuration file is ethercat.xml
Diagnostic
Firmware supports common diagnostic in the dual-port-memory of the loadable firmware.