Gateway Solutions download package 2023-07-1

Release Notes
Status

RELEASED

Date2023-07-1
VersionV1.0500.230630.44454(2023-06-30)
Summary
  • Updated memory component support
  • Update of driver and tools to the lasted released version
  • Update of configuration and migration manuals

Note: We reserve the right to make technical changes without prior notice.

Phase Out Information

Product Updates for supporting new flash-types

An essential aspect of Hilscher's product lifecycle management process is around maintaining existing products to guarantee sustained availability for our valued customers.

The flash component used in numerous Hilscher products was discontinued as part of the manufacturer's portfolio streamlining. In order to offer our customers a long-term and future-proof alternative, we will use flash components that support the SFDP (Serial Flash Discoverable Parameter) standard. This ensures that our products remain compatible with evolving hardware requirements and ensures a seamless user experience.

In scenarios where protocol firmware versions come in two variants within the software download package, both versions are fully compatible with the hardware currently being shipped.

Through a Product Change Notification (PCN) in the upcoming months, Hilscher will inform that, starting from a new hardware revision, the corresponding firmware generation, specifically the latest version available in the software download package, must be used.

Below you will find a list of firmware versions from which an unlimited compatibility is given:

  • netTAP 151 → V1.4.0.5
  • netTAP 151 CCIES → V1.3.0.4

Other products are not affected by the flash update.

To provide clarity on firmware generation status and versioning, we have outlined a comprehensive description, available at the following link: https://hilscher.atlassian.net/wiki/x/KQBQBg

In scenarios with two variants, one firmware is then used for an evolution without API and function change, only including support for Flash types supporting SFDP, and the other one, the latest recommended firmware generation, represents the latest technology maintained and enhanced by new features. 

Hilscher will send a PCN document with detailed descriptions of the compatibility of each affected product with at least 6 months notice before the change, to ensure a smooth update-timeframe for the firmware.

Migration guide netTAP 100 V2.0.0.0

Migration to Firmware V2.0.0.x for netTAP 100

 Click here to expand...

Due to a major stack update of the firmware, the DTMs for the netTAP 100 are changed in SYCON.net. During the configuration of a netTAP 100 devices it is possible to choose between different DTMs in order to define the desired protocol combination:

To enable the configuration of netTAP 100 gateways with the old and new firmware, use the following DTMs for the respective firmware version:

DTM nameFirmware version
Open Modbus/TCP V3V2.0.0.x
POWERLINK Controlled Node V3V2.0.0.x
PROFINET IO Controller V3Do not use. Please use PROFINET IO Controller instead.
Open Modbus/TCPV1.7.0.x
POWERLINK Controlled NodeV1.7.0.x
PROFINET IO ControllerV1.7.0.x
OthersV2.0.0.x and V1.7.0.x

The version of the firmware is shown when the desired conversion is selected. (See here (1)).

The EDS files related to the firmware version are provided in different folders:

..\ Firmware,_EDS,_Examples,_Webpages\Firmware_&_EDS\netTAP 100\DeviceDescription\V1.7.0.x and V2.0.0.x respectively

Getting Started

Software installation

 Click here to expand..

Softaware components

The following table shows the components included in the download package:

NameVersionDescriptionMandatory
SYCON.netV1.0500.230630.44454Configuration and Firmware downloadyes
USB Driver06/08/2021 6.0.23.0Allows the configuration of the devices via USByes
netSCRIPT DebuggerV1.0.15893.0Enables the debugging of user specific netSCRIPT programsno
LuaV5.1.4-46Lua is used as programming language for netSCRIPTno

First Steps

 Click here to expand...
  1. Install the above mentioned software components.

  2. Connect the power supply to the device.

  3. Connect the device to the PC for configuration using the appropriate method. For further details, please see folder “netTAP_Manuals” under “Documentation” of this DVD.

  4. Start SYCON.net.

  5. In the device catalog, select the gateway to be configured and place it in the network view (2).

  6. Open the configuration menu (right click) of the gateway (3).

  7. Select the desired conversion under "Configuration" (4).

  8. Select and download the firmware to the gateway (5).

  9. Set up a network configuration and conversion rules via SYCON.net. For more information see folder “SYCON.net Configuration Software” under “\Documentation\Configuration_Manuals” in this DVD and the “Documentation” section).

  10. Download the configuration to the gateway (6).
  11. The gateway is automatically restarted and starts the desired firmware with the corresponding configuration.
  12. Integrate the gateway into the desired application.

Documentation

 Click here to expand...

The documentation for all hard- and software components are available in the folder “Documentation” in this DVD. For more information on how to configure a specific device, see the following table:

DocumentSectionPage
Configuration of Gateway and Proxy Devices OI 12 EN3.2 Configuration of a NT 50 as a Gateway21
3.3 Configuration of a NT 100 or NB 100 as a Gateway39
3.4 Configuration of a NT 100 as Proxy57
3.5 Configuration of the NT 151-RE-RE73
3.6 Configuration of the NT 151-CCIES-RE101
3.7 Configuration of the NL 51N-DPL as Proxy122
Documentation

The documentation can be downloaded at:

Device Driver


Firmware Version


VersionHardware platform
V1.1.0.0netLINK PROXY

Software & Tools


Configuration Tool

SYCON.net

Operating System Windows 2000Windows XP SP3Windows Vista SP2Windows 7Windows 8Windows 8.1Windows 10
Status(error)(error)(tick)(tick)(tick)

(tick)

(tick)

netTAP Protocol Conversions


netTAP 50

Secondary Network (X3)
EtherNet/IPOpen Modbus/TCPPROFINET IOASCIIMBR
MasterSlaveMasterSlave
Primary Network (X2)ASCII(tick)(tick)(tick)(tick)(tick)n.an.a
CC-LinkSlave(tick)(tick)(tick)(tick)(tick)(tick)(tick)
CANopenMastern.a(tick)(tick)n.a(tick)(tick)(tick)

Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)
DeciveNetMastern.a(tick)(tick)n.a(tick)(tick)(tick)

Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Profibus-DPMastern.a(tick)(tick)n.a(tick)(tick)(tick)

Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)
ModbusRTU (tick)(tick)(tick)(tick)(tick)n.an.a


netTAP 100

Secondary Network (X3)
ASCIICC-LinkCANopenDeviceNetProfibus-DPModbusRTUnetSCRIPT3964R
SlaveMasterSlaveMasterSlaveMasterSlave
Primary Network (X2)CANopenMaster

(tick)

(tick)n.a(tick)n.a(tick)n.a(tick)(tick)(tick)(tick)
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
DeciveNetMaster(tick)(tick)n.a(tick)n.a(tick)n.a(tick)(tick)(tick)(tick)
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Profibus-DPMaster(tick)(tick)n.a(tick)n.a(tick)n.a(tick)(tick)(tick)(tick)
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)

(tick)

(tick)(tick)
EtherCATMaster(tick)(tick)n.a(tick)n.a(tick)n.a(tick)(tick)(tick)(tick)
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
EtherNet/IPMaster(tick)(tick)n.a(tick) 1n.a(tick)n.a(tick)(tick)(tick)(tick)
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Open Modbus/TCP(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
POWERLINKSlave(tick)(tick)(tick)(tick) 1(tick)(tick)(tick)(tick)(tick)(tick)(tick)
PROFINET IOMaster(tick)1(tick)1n.a(tick)1n.a(tick)1n.a(tick)1(tick)1(tick)1(tick)1
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Sercos 3Master(tick)(tick)n.a(tick)n.a(tick)n.a(tick)(tick)(tick)(tick)
Slave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)

netTAP 100

Expiring and not updated conversions

V1.7.0.8

Alternative: netTAP 151

EtherNet/IPEtherNet/IPOpen Modbus/TCP
MasterSlave
EtherCATMastern.a

(tick) 1

(tick) 1
EtherCATSlaven.a(tick) 1(tick) 1
EtherNet/IPMastern.a(tick) 1(tick) 1
EtherNet/IPSlaven.a(tick) 1(tick) 1
Open Modbus/TCPn.a(tick) 1(tick) 1
POWERLINKSlaven.a(tick) 1(tick) 1
PROFINET IOMastern.a(tick) 1(tick) 1
PROFINET IOSlave(tick) 1(tick) 1(tick) 1
Sercos 3Mastern.a(tick) 1(tick) 1
Sercos 3Slaven.a(tick) 1(tick) 1

1 Conversions were not updated. Their version number is: V1.7.0.8. Please see "Migration to Firmware V2.0.0.0 for netTAP 100" for more details.


netTAP 151 RE-RE

Secondary Network (X3)
EtherCATEtherNet/IPOpen Modbus/TCPPOWERLINKPROFINET IOSercos 3
MasterSlaveMasterSlaveSlaveMasterSlaveMasterSlave

Primary Network (X2)

EtherCATSlave(tick)(tick)(tick)(tick)(tick)n.a.(tick)(tick)(tick)n.a.
EtherNet/IPSlave(tick)n.a.(tick)(tick)(tick)n.a.(tick)(tick)(tick)n.a.
Open Modbus/TCP(tick)n.a.(tick)n.a.(tick)n.a.(tick)n.a.(tick)n.a.
POWERLINKSlave(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
PROFINET IOSlave(tick)n.a.(tick)n.a.(tick)n.a.(tick)(tick)(tick)n.a.
Sercos 3Slave(tick)(tick)(tick)(tick)(tick)n.a.(tick)(tick)(tick)(tick)
NT 151-CCIES-RE/PNSProfinet
Slave
CC-Link IE FieldSlave(tick)

netLINK/TAP Hardware and Protocols
netLINK PROXYPROFIBUS
SlaveMaster
PROFINETSlave(tick)(error)
Master(error)(error)
netTAP PROXYPROFIBUS
SlaveMaster
PROFINETSlave(tick)(tick)
Master(tick)(tick)

Product Download Package