PROFINET FSU (Fast Startup) und EtherNetIP QuickConnect

PROFINET FSU (Fast Startup) und EtherNetIP QuickConnect

Q

Do the LFWs for netX 90 meet the FSU and Quickconnect requirements?

A

Yes, the PROFINET IO-Device LFW (PNS) supports FSU, EtherNetIP LFW (EIS) supports Quickconnect.

(warning) Please note that the communication firmware (LFW) does not automatically meet the requirement. The start up sequence of the user application on host side must be implemented in a proper way in order to meet the FSU/QuickConnect requirement. I.e. unnecessary code exection must be avoided. The Hilscher host demo applications may not meet this requirement, since the start up is not optimized and debug/diagnosis messages are output via a console.