PLC Demo Example PROFIdrive AC1

Two different examples were prepared using PLC Siemens S7-1500. The first example performs motor control via ProfiDrive with another Hilscher solution, the NIC52-RE, without the need for any PC. In the second, more detailed visualization is performed by using WinCC PC Runtime instead of NIC52-RE.

Demo System

A minimum of TIA Portal 15.1 must be installed to open the TIA Portal files.

S7-1500 PLC is not working without SD card. Get Siemens SD Card before starting.

PROFIdrive Example with NIC52-RE

The detailed PLC Startup Guide for the NIC52-RE based ProfiDrive Example can be accessed from the PLC Startup Guide - NIC52-RE based PROFIdrive Example.

PLC Settings

NIC52-RE Device Settings

NETX90-MC Device Settings

PLC Settings

NIC52-RE Device Settings

NETX90-MC Device Settings

  • ProfiNet Interface: X2

  • IP address: 172.20.11.88

  • Subnet Mask: 255.255.255.0

  • ProfiNet Device Name: nic52pns

  • IP address: 172.20.11.92

  • Subnet Mask: 255.255.255.0

  • ProfiNet Interface: netx90repns

  • IP address: 172.20.11.91

  • Subnet Mask: 255.255.255.0

 

 

The following table describes the functions of the DIP switches on the NIC52-RE.

DIP Index

Speed[RPM] - (Left side DIP switches)

Meaning

DIP Index

Speed[RPM] - (Left side DIP switches)

Meaning

1

12.5%

Set motor speed to 12.5%.

2

25.0%

Set motor speed to 25%.

3

37.5%

Set motor speed to 37.5%.

4

50%

Set motor speed to 50%.

5

62.5%

Set motor speed to 62.5%.

6

75%

Set motor speed to 75%.

7

87.5%

Set motor speed to 87.5%.

8

100%

Set motor speed to 100%.

DIP Index

Control - (Right side DIP switches)

Meaning

DIP Index

Control - (Right side DIP switches)

Meaning

1

Start

0 - Stop motor, 1 - Start motor

2

Dir

Motor DIrection: 0-CCW / 1-CW.

3

-

-

4

-

-

5

-

-

6

-

-

7

Reset

Reset ProfiDrive: 0-Reset disable, 1-Reset enable.

8

Power Enable

ProfiDrive Power: 0-Disabled, 1-Enable

 

 

The LEDs on the NIC52-RE show the motor RPM. When the middle two LEDs are lit, the motor speed is 0. The 8 LEDs on the right side show the CW direction and the ones on the left show the CCW direction. Each LED indicates a 12.5% motor speed.

Demo System

PROFIdrive Example with WinCC PC Runtime

 

 

PLC Settings

WinCC PC Runtime

NETX90-MC Device Settings

PLC Settings

WinCC PC Runtime

NETX90-MC Device Settings

  • ProfiNet Interface: X2

  • IP address: 172.20.11.88

  • Subnet Mask: 255.255.255.0

  • IP address: 172.20.11.254

  • Subnet Mask: 255.255.255.0

  • ProfiNet Interface: netx90repns

  • IP address: 172.20.11.91

  • Subnet Mask: 255.255.255.0

WinCC PC Runtime Application

Â