PLC Demo Example PROFIdrive AC1

PLC Demo Example PROFIdrive AC1

Two different examples were prepared using PLC Siemens S7-1500. The first example performs motor control via ProfiDrive with another Hilscher solution, the NIC52-RE, without the need for any PC. In the second, more detailed visualization is performed by using WinCC PC Runtime instead of NIC52-RE.

Demo System

A minimum of TIA Portal 15.1 must be installed to open the TIA Portal files.

S7-1500 PLC is not working without SD card. Get Siemens SD Card before starting.

PROFIdrive Example with NIC52-RE

The detailed PLC Startup Guide for the NIC52-RE based ProfiDrive Example can be accessed from the PLC Startup Guide - NIC52-RE based PROFIdrive Example.

PLC Settings

NIC52-RE Device Settings

NETX90-MC Device Settings

PLC Settings

NIC52-RE Device Settings

NETX90-MC Device Settings

  • ProfiNet Interface: X2

  • IP address: 172.20.11.88

  • Subnet Mask: 255.255.255.0

  • ProfiNet Device Name: nic52pns

  • IP address: 172.20.11.92

  • Subnet Mask: 255.255.255.0

  • ProfiNet Interface: netx90repns

  • IP address: 172.20.11.91

  • Subnet Mask: 255.255.255.0

 

 

The following table describes the functions of the DIP switches on the NIC52-RE.

DIP Index

Speed[RPM] - (Left side DIP switches)

Meaning

DIP Index

Speed[RPM] - (Left side DIP switches)

Meaning

1

12.5%

Set motor speed to 12.5%.

2

25.0%

Set motor speed to 25%.

3

37.5%

Set motor speed to 37.5%.

4

50%

Set motor speed to 50%.

5

62.5%

Set motor speed to 62.5%.

6

75%

Set motor speed to 75%.

7

87.5%

Set motor speed to 87.5%.

8

100%

Set motor speed to 100%.

DIP Index

Control - (Right side DIP switches)

Meaning

DIP Index

Control - (Right side DIP switches)

Meaning

1

Start

0 - Stop motor, 1 - Start motor

2

Dir

Motor DIrection: 0-CCW / 1-CW.

3

-

-

4

-

-

5

-

-

6

-

-

7

Reset

Reset ProfiDrive: 0-Reset disable, 1-Reset enable.

8

Power Enable

ProfiDrive Power: 0-Disabled, 1-Enable

 

 

The LEDs on the NIC52-RE show the motor RPM. When the middle two LEDs are lit, the motor speed is 0. The 8 LEDs on the right side show the CW direction and the ones on the left show the CCW direction. Each LED indicates a 12.5% motor speed.

Demo System

PROFIdrive Example with WinCC PC Runtime

 

 

PLC Settings

WinCC PC Runtime

NETX90-MC Device Settings

PLC Settings

WinCC PC Runtime

NETX90-MC Device Settings

  • ProfiNet Interface: X2

  • IP address: 172.20.11.88

  • Subnet Mask: 255.255.255.0

  • IP address: 172.20.11.254

  • Subnet Mask: 255.255.255.0

  • ProfiNet Interface: netx90repns

  • IP address: 172.20.11.91

  • Subnet Mask: 255.255.255.0

WinCC PC Runtime Application

 

Related content

PLC Startup Guide - WinCC PC Runtime based PROFIdrive Example
PLC Startup Guide - WinCC PC Runtime based PROFIdrive Example
More like this
netX 90 - PROFINET IO Device - Examples
netX 90 - PROFINET IO Device - Examples
Read with this
PLC Startup Guide - NIC52-RE based PROFIdrive Example
PLC Startup Guide - NIC52-RE based PROFIdrive Example
More like this
PNS TIA Portal netMOTION
PNS TIA Portal netMOTION
Read with this
PROFIdrive Application Class
PROFIdrive Application Class
More like this
PROFIdrive Implementation Guide
PROFIdrive Implementation Guide
Read with this